KROHNE vortex flowmeters are designed for reliable measurement of liquids, gases and saturated or superheated steam in industrial process and utility applications. The product range includes OPTISWIRL 2100, OPTISWIRL 4200 and OPTISWIRL 5080, together with OPTISWIRL 2000 / 4000 sensor components and VFC signal converters. Available configurations support steam flow measurement, energy management, high-temperature processes, compressed air monitoring, industrial gas measurement and auxiliary utility systems.

Description

Product Overview

KROHNE vortex flowmeters are designed for measuring the flow of liquids, gases and steam in industrial process systems, utility networks and energy management applications.

Based on the Karman vortex shedding principle, these instruments determine flow velocity by detecting vortices generated when the process medium passes a specially designed bluff body inside the measuring tube.

The OPTISWIRL product family offers robust flow measurement solutions for saturated steam, superheated steam, compressed air, industrial gases, water, thermal oil and other process liquids.

OPTISWIRL 2100 provides an economical solution for basic utility applications, OPTISWIRL 4200 offers integrated pressure and temperature compensation for advanced energy management, while OPTISWIRL 5080 is designed for demanding high-temperature applications.

Product Features
– Karman vortex shedding measurement principle.
– Liquid, gas and steam flow measurement.
– Saturated and superheated steam measurement.
– Compressed air flow monitoring.
– Industrial gas measurement.
– Water and process liquid measurement.
– Integrated temperature sensor on supported models.
– Optional integrated pressure measurement.
– Mass flow calculation.
– Standardized volume flow calculation.
– Integrated gross and net heat calculation on supported models.
– Advanced Vortex Frequency Detection (AVFD).
– Adaptive signal filtering and conditioning.
– High vibration immunity on supported configurations.
– Flanged and wafer measuring tube designs.
– Compact and remote converter configurations.
– Dual sensor configurations for redundant measurement.
– 4–20 mA analog output.
– HART communication.
– PROFIBUS PA.
– FOUNDATION Fieldbus.
– SIL 2 / SIL 3 configurations on selected models.
– ATEX and IECEx explosion protection options.
– OPTICHECK on-site verification support.

Product Series

1. OPTISWIRL 2100 – Basic Utility Vortex Flowmeter
– OPTISWIRL 2100 C – Compact Version
– OPTISWIRL 2100 F – Remote Version
– OPTISWIRL 2100 Flanged Version
– OPTISWIRL 2100 Wafer Version
– OPTISWIRL 2100 F1R / F2R Reduced Nominal Diameter Versions
– Liquid Flow Measurement
– Wet Gas Flow Measurement
– Saturated Steam Measurement
– Superheated Steam Measurement
– Compressed Air Monitoring
– Industrial Utility Applications
– Basic Process Flow Monitoring
– AVFD Signal Filtering
– HART 7 Communication
– DN15–300 Flanged Connections
– Wafer Connections up to DN100
– Operating Temperature up to +240°C

2. OPTISWIRL 4200 – Advanced Utility and Energy Management Vortex Flowmeter
– OPTISWIRL 4200 C – Compact Version
– OPTISWIRL 4200 F – Remote Version
– OPTISWIRL 4200 Flanged Version
– OPTISWIRL 4200 Sandwich Version
– OPTISWIRL 4200 Dual Version
– OPTISWIRL 4200 F1R / F2R Reduced Diameter Versions
– Integrated Temperature Measurement
– Optional Integrated Pressure Measurement
– Saturated Steam Measurement
– Superheated Steam Measurement
– Liquid and Gas Flow Measurement
– Direct Mass Flow Calculation
– Standard Volume Flow Calculation
– Gross and Net Heat Calculation
– Steam and Condensate Energy Monitoring
– Hot Water Energy Measurement
– Industrial Energy Management
– ISO 50001 Energy Monitoring Applications
– Advanced Vortex Frequency Detection (AVFD)
– SIL 2 / SIL 3 Configurations
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– DN15–300 Flanged Connections
– Wafer Connections up to DN100
– Operating Temperature up to +240°C

3. OPTISWIRL 5080 – High-Temperature Vortex Flowmeter
– OPTISWIRL 5080 Flanged Version
– OPTISWIRL 5080 Sandwich Version
– OPTISWIRL 5080 Compact Configuration
– OPTISWIRL 5080 Remote Configuration
– OPTISWIRL 5080 Dual Configuration
– High-Temperature Liquid Measurement
– High-Temperature Gas Measurement
– Saturated Steam Measurement
– Superheated Steam Measurement
– Thermal Oil Flow Measurement
– Industrial Heat Transfer Systems
– Steam Boiler Monitoring
– High-Temperature Process Applications
– Adaptive Signal Filtering
– Advanced Signal Conditioning
– High Vibration Immunity
– 4–20 mA Output
– HART Communication
– DN15–300 Flanged Connections
– Wafer Connections up to DN200
– Operating Temperature up to +427°C
– Pressure Ratings up to PN160 / ASME Class 1500

4. OPTISWIRL 2000 – Vortex Flow Sensor
– OPTISWIRL 2000 Standard Sensor
– Stainless Steel Measuring Tube
– Flanged Sensor Configuration
– Wafer Sensor Configuration
– Integrated Nominal Diameter Reduction Options
– Industrial Liquid Measurement
– Gas Flow Measurement
– Steam Measurement
– Utility Pipeline Applications
– Replacement Flow Sensor
– Compatible VFC 100 Signal Converter
– DN15–300 Flanged Connections
– Wafer Connections up to DN100

5. OPTISWIRL 4000 – Vortex Flow Sensor
– OPTISWIRL 4000 F – Remote Sensor Version
– Flanged Measuring Tube
– Wafer Measuring Tube
– Integrated Temperature Measurement Options
– Industrial Liquid Measurement
– Gas and Steam Measurement
– Utility and Process Applications
– Replacement Flow Sensor
– Compatible VFC 200 Signal Converter
– DN15–300 Flanged Connections
– Wafer Connections up to DN100

6. VFC 100 – Basic Vortex Signal Converter
– VFC 100 Compact Configuration
– VFC 100 Remote Configuration
– OPTISWIRL 2000 Sensor Integration
– Basic Vortex Signal Processing
– Flow Rate Calculation
– 4–20 mA Output
– HART Communication
– Industrial Control System Integration
– Replacement and Retrofit Applications

7. VFC 200 – Advanced Vortex Signal Converter
– VFC 200 Compact Configuration
– VFC 200 Remote Configuration
– OPTISWIRL 4000 Sensor Integration
– Advanced Vortex Signal Processing
– Advanced Vortex Frequency Detection (AVFD)
– 4–20 mA Output
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Integrated Diagnostics
– Energy Calculation Functions on Supported Configurations
– Industrial Automation Integration
– Replacement and Retrofit Applications

Available Product Configurations

Measuring Tube Designs
– Flanged Vortex Flowmeters
– Wafer / Sandwich Vortex Flowmeters
– Compact Measuring Assemblies
– Remote Measuring Assemblies
– Dual Sensor Flowmeters
– Reduced Nominal Diameter Configurations
– High-Temperature Measuring Assemblies

Process Media
– Water
– Hot Water
– Cooling Water
– Saturated Steam
– Superheated Steam
– Compressed Air
– Natural Gas
– Industrial Gases
– Wet Gases
– Thermal Oil
– Heat Transfer Liquids
– General Industrial Process Liquids

Process Connections
– DIN Flanges
– ASME Flanges
– Wafer Connections
– Sandwich Connections
– Reduced Diameter Connections
– Industrial Pipeline Connections

Electrical & Communication
– 4–20 mA Analog Output
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Integrated Pressure Measurement
– Integrated Temperature Measurement
– Flow Totalization
– Mass Flow Calculation
– Energy Calculation
– Gross and Net Heat Calculation

Safety & Certifications
– ATEX Explosion Protection
– IECEx Explosion Protection
– SIL 2 / SIL 3 Configurations on Supported Models
– IP66 / IP67 Protection
– Functional Safety Applications
– OPTICHECK On-Site Verification

Key Product Specifications
– OPTISWIRL 2100: DN15–300; up to +240°C
– OPTISWIRL 4200: DN15–300; up to +240°C
– OPTISWIRL 5080: DN15–300; up to +427°C
– OPTISWIRL 2000: DN15–300 flange; DN15–100 wafer
– OPTISWIRL 4000: DN15–300 flange; DN15–100 wafer
– VFC 100: Basic signal conversion
– VFC 200: Advanced signal conversion

Specifications represent selected product-family configurations. Actual pressure ratings, temperature limits, process connections, communication interfaces and approvals depend on the exact model and configuration. OPTISWIRL 2000 and 4000 are sensor components, not independent complete flowmeters.

Industrial Applications
– Industrial steam distribution networks
– Steam boiler monitoring
– Power generation facilities
– District heating systems
– Industrial energy management
– Compressed air distribution
– Natural gas consumption monitoring
– Chemical processing plants
– Petrochemical production facilities
– Petroleum refineries
– Food and beverage manufacturing
– Pharmaceutical production
– Thermal oil heating systems
– Industrial heat transfer systems
– Water supply and distribution
– Cooling water circulation
– Industrial utility systems
– Process skid equipment
– Industrial automation systems
– Energy efficiency monitoring

More Models & Technical Specifications

OPTISWIRL 2100

OPTISWIRL 2100 is an economical vortex flowmeter designed for basic utility applications across different industries.

It measures conductive and non-conductive liquids, wet gases, saturated steam and superheated steam. Its AVFD technology supports stable signal detection under demanding process conditions.

The product is suitable for compressed air monitoring, basic steam consumption measurement, water distribution and general industrial utility services.

OPTISWIRL 4200

OPTISWIRL 4200 is designed for advanced utility applications and industrial energy management.

It integrates temperature measurement and can optionally include pressure measurement. This enables direct calculation of mass flow, normalized volume flow and energy values for supported steam and hot water applications.

Its optional gross and net heat calculation makes it particularly useful for steam distribution, condensate monitoring, boiler systems and ISO 50001 energy management.

The device is also available in redundant dual configurations and remote installation versions, with SIL 2 / SIL 3 certification for supported safety applications.

OPTISWIRL 5080

OPTISWIRL 5080 is designed for high-temperature industrial processes, including saturated and superheated steam above +240°C.

It supports measurement of liquids, gases and steam at temperatures up to +427°C. Its adaptive filtering and signal conditioning improve low-flow performance and help reduce the impact of pipeline vibration.

Typical applications include high-temperature steam systems, thermal oil circulation, industrial boilers, refineries and heat transfer processes.

OPTISWIRL 2000 / 4000 Sensors

OPTISWIRL 2000 and OPTISWIRL 4000 are vortex flow sensor components designed for combination with compatible VFC signal converters.

OPTISWIRL 2000 is combined with the VFC 100 to form an OPTISWIRL 2100 measuring system, while OPTISWIRL 4000 is combined with the VFC 200 for corresponding remote configurations.

These components are relevant for sensor replacement, maintenance and industrial retrofit projects.

VFC 100 / VFC 200 Signal Converters

VFC signal converters process vortex sensor signals and provide the required outputs for industrial automation systems.

VFC 100 supports basic flow measurement configurations, while VFC 200 offers advanced signal processing and communication options for compatible sensor assemblies.

Exact compatibility must be checked against the complete instrument designation and generation.

Actual product selection depends on process medium, flow range, pipeline diameter, operating pressure, temperature, density, viscosity, steam conditions, installation requirements and required output signals.

For accurate product selection and replacement, please provide the complete KROHNE model number, measured medium, pipe diameter, flow rate, pressure, operating temperature and required communication interface when making an inquiry.

Looking for other KROHNE vortex flowmeters, replacement sensors, signal converters or specific accessories? Please contact our online customer service team for further assistance.