Description
Product Overview
KROHNE vortex flowmeters are designed for accurate and reliable measurement of liquids, gases, and steam in industrial process systems.
Operating on the vortex shedding principle, these instruments measure the frequency of vortices generated when fluid flows around a bluff body installed inside the measuring tube. The vortex frequency is proportional to the fluid velocity and is used to calculate volumetric flow.
KROHNE offers vortex flow measurement solutions for basic utility applications, advanced energy management, demanding process conditions, and high-temperature industrial applications.
The OPTISWIRL product family includes compact and remote configurations, integrated temperature measurement, optional pressure compensation, and advanced signal processing technologies.
The OPTISWIRL 4200 is particularly suitable for steam and energy management systems, while the OPTISWIRL 5080 is designed for high-temperature process applications. The OPTISWIRL 2100 provides an economical solution for basic industrial utility measurement.
Product Features
– Vortex shedding measurement principle.
– Suitable for liquid, gas, and steam measurement.
– No moving mechanical measuring components.
– Robust industrial construction.
– Suitable for saturated and superheated steam.
– Integrated temperature measurement on selected models.
– Optional integrated pressure measurement.
– Mass flow calculation using pressure and temperature compensation on supported models.
– Integrated gross and net heat calculation on selected configurations.
– Advanced Vortex Frequency Detection (AVFD) technology.
– High vibration immunity and signal stability.
– Compact and remote transmitter configurations.
– Flanged and wafer-type process connections.
– 4–20 mA analog output.
– HART communication.
– PROFIBUS PA and FOUNDATION Fieldbus on supported models.
– SIL 2/3 certified configurations for selected safety applications.
Product Series
1. OPTISWIRL 2100 – Basic Utility Vortex Flowmeter
– OPTISWIRL 2100 C – Compact Version
– OPTISWIRL 2100 F – Remote Version
– OPTISWIRL 2100 Flanged Version
– OPTISWIRL 2100 Wafer Version
– OPTISWIRL 2100 F1R / F2R
– Liquid Flow Measurement
– Wet Gas Flow Measurement
– Saturated Steam Measurement
– Superheated Steam Measurement
– Industrial Utility Flow Measurement
– Compressed Air and Gas Monitoring
2. OPTISWIRL 4200 – Advanced Vortex Flowmeter
– OPTISWIRL 4200 C – Compact Version
– OPTISWIRL 4200 F – Remote Version
– OPTISWIRL 4200 Flanged Version
– OPTISWIRL 4200 Wafer Version
– OPTISWIRL 4200 Dual Version
– OPTISWIRL 4200 with Integrated Temperature Sensor
– OPTISWIRL 4200 with Integrated Pressure Sensor
– OPTISWIRL 4200 with Gross and Net Heat Calculation
– OPTISWIRL 4200 with Flow Computer
– OPTISWIRL 4200 with Advanced Vortex Frequency Detection
– OPTISWIRL 4200 for Steam Measurement
– OPTISWIRL 4200 for Energy Management Systems
3. OPTISWIRL 5080 – High-Temperature Vortex Flowmeter
– OPTISWIRL 5080 Flanged Version
– OPTISWIRL 5080 Wafer Version
– OPTISWIRL 5080 Compact Configuration
– OPTISWIRL 5080 Remote Configuration
– OPTISWIRL 5080 High-Temperature Version
– OPTISWIRL 5080 for Saturated Steam
– OPTISWIRL 5080 for Superheated Steam
– OPTISWIRL 5080 for Thermal Oil
– OPTISWIRL 5080 for Industrial Gas Measurement
– OPTISWIRL 5080 with High-Pressure Connections
4. OPTISWIRL 4000 – Vortex Flow Sensor
– OPTISWIRL 4000 Flanged Flow Sensor
– OPTISWIRL 4000 Wafer Flow Sensor
– OPTISWIRL 4000 with Nominal Diameter Reduction
– OPTISWIRL 4000 Stainless Steel Sensor
– OPTISWIRL 4000 Special Alloy Configuration
– Industrial Liquid Flow Sensor
– Gas and Steam Flow Sensor
5. VFC 200 – Vortex Flow Converter
– VFC 200 Compact Converter
– VFC 200 Remote Field Housing
– VFC 200 with 4–20 mA Output
– VFC 200 with HART Communication
– VFC 200 with PROFIBUS PA
– VFC 200 with FOUNDATION Fieldbus
– VFC 200 Advanced Diagnostics
– VFC 200 Integrated Energy Calculation
Note: OPTISWIRL 4000 and VFC 200 are included as legacy and replacement identification entries for compatible earlier-generation installations. Confirm sensor-converter compatibility before ordering.
Available Product Configurations
Vortex Flow Measurement
– Liquid Flow Measurement
– Gas Flow Measurement
– Saturated Steam Measurement
– Superheated Steam Measurement
– Wet Gas Measurement
– Industrial Utility Measurement
– Compressed Air Monitoring
– Thermal Oil Measurement
Pressure & Temperature Compensation
– Integrated Temperature Measurement
– Integrated Pressure Measurement
– Pressure Compensation
– Temperature Compensation
– Mass Flow Calculation
– Standard Volume Flow Calculation
– Gross Heat Measurement
– Net Heat Measurement
– Steam and Condensate Energy Monitoring
Mechanical Configurations
– Flanged Flowmeter Designs
– Wafer / Sandwich Designs
– Compact Installation
– Remote Transmitter Installation
– Stainless Steel Measuring Tubes
– Special Alloy Wetted Materials
– Different Nominal Diameters
– High-Pressure Configurations
– High-Temperature Configurations
Electrical & Communication
– 2-Wire 4–20 mA Outputs
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Pulse and Frequency Outputs
– Integrated Digital Display
– Remote Signal Converter
– Industrial Control System Integration
Key Product Specifications
– OPTISWIRL 2100: DN15–300; steam up to +240°C
– OPTISWIRL 4200: DN15–300; steam up to +240°C
– OPTISWIRL 4200 Wafer: Up to DN100
– OPTISWIRL 5080: DN15–300; up to +427°C
– OPTISWIRL 5080 Wafer: Up to DN200
– OPTISWIRL 5080 Flanged: Up to PN160 / ASME 1500 lb
Specifications refer to official product-family documentation. Maximum temperature and pressure depend on sensor size, process connection and selected configuration. OPTISWIRL 5080 documentation specifies up to +430°C in some technical publications, while regional product listings quote +427°C.
Industrial Applications
– Industrial steam distribution networks
– Power generation facilities
– Boiler and steam systems
– Chemical processing plants
– Petrochemical production
– Oil and gas facilities
– Compressed air systems
– Industrial gas distribution
– Food and beverage manufacturing
– Pharmaceutical production
– Heating and cooling systems
– District energy networks
– Thermal oil circulation systems
– Industrial utility monitoring
– Energy management systems
– Automated manufacturing facilities
More Models & Technical Specifications
OPTISWIRL 2100 is an economical vortex flowmeter for basic utility applications. It measures liquids, wet gases, saturated steam and superheated steam. Its compact and remote versions support different industrial installation requirements. An integrated nominal diameter reduction option can extend the measuring range in selected pipeline applications.
OPTISWIRL 4200 is an advanced vortex flowmeter for industrial utility applications and energy management. It includes an integrated temperature sensor and can optionally include pressure measurement. The instrument can calculate mass flow, normalized volume flow, gross heat and net heat for supported steam and hot water applications.
OPTISWIRL 4200 uses Advanced Vortex Frequency Detection (AVFD) technology to improve signal filtering and measurement stability under demanding process conditions. Selected configurations are certified for SIL 2/3 safety-related applications.
OPTISWIRL 5080 is designed for demanding high-temperature applications involving liquids, gases and steam. It supports process temperatures up to approximately +427°C according to the regional product listing and up to +430°C in its technical documentation. It is suitable for steam boilers, thermal oil systems and high-temperature industrial processes.
The OPTISWIRL 4000 sensor and VFC 200 converter are included for identification of compatible earlier-generation installations. Replacement selection must take into account the sensor version, converter configuration, wiring, measurement range and communication requirements.
Actual product selection depends on fluid type, nominal diameter, flow velocity, operating pressure, temperature, density, viscosity, process connection, installation conditions and required communication protocol.
For accurate product selection and replacement, please provide the complete KROHNE model number, nominal diameter, measured medium, operating pressure, operating temperature, required flow range, process connection and existing equipment details when making an inquiry.
Looking for other KROHNE vortex flowmeter models, replacement converters, or specific accessories? Please contact our online customer service team for further assistance.