Description
Product Overview
KROHNE variable area flowmeters, also known as rotameters, are designed for measuring the volumetric flow of liquids and gases in industrial process systems.
These instruments operate on the variable area measurement principle. A float moves inside a vertically positioned tapered measuring tube in response to the flow rate, providing a direct indication of the measured medium’s flow.
KROHNE offers both metal tube and glass tube designs, covering applications from extremely low flow rates to demanding industrial process conditions.
The H250 family provides robust metal tube measurement for industrial applications, while the DK series covers low-flow measurement and analytical systems. VA40 and VA45 offer glass tube solutions for applications requiring direct visual flow indication.
Product Features
– Variable area flow measurement principle.
– Direct mechanical flow indication.
– Liquid and gas flow measurement.
– Metal tube and glass tube constructions.
– No external power supply required for basic mechanical indication.
– Low-flow measurement capabilities.
– High-pressure configurations on selected models.
– High-temperature process configurations.
– Stainless steel and special alloy materials.
– Corrosion-resistant material options.
– PTFE-lined versions on selected models.
– Hygienic process connections.
– Mechanical and electronic indicators.
– 4–20 mA analog output options.
– HART communication on supported models.
– PROFIBUS PA options on supported configurations.
– Pulse output and totalizer options.
– Adjustable limit switches.
– Continuous Float Monitoring (CFM) on selected models.
– SIL 2 configurations on selected models.
– ATEX and IECEx explosion protection options.
– Compact installation and simple maintenance.
Product Series
1. H250 M40 – Industrial Metal Tube Variable Area Flowmeter
– H250 M40 Standard Version
– H250 M40R Remote Version
– H250F M40 Hygienic Version
– H250H M40 High-Temperature Version
– H250C M40 PTFE-Lined Version
– H250U M40 Special Application Version
– H250 M40 Low Flow Configuration
– Mechanical Pointer Indicator
– 4–20 mA Electronic Output
– HART 7 Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Integrated Totalizer
– Pulse Output
– Adjustable Limit Switches
– Continuous Float Monitoring (CFM)
– Liquid and Gas Measurement
– DN15–150 Process Connections
– Operating Temperature: -196 to +400°C
– Pressure Ratings up to 1000 barg on applicable configurations
2. H250 M40 Low Flow – Low-Flow Metal Tube Flowmeter
– Low-Flow Liquid Measurement
– Low-Flow Gas Measurement
– Precision Chemical Dosing
– Laboratory Process Monitoring
– Analytical Gas Sampling
– Mechanical Flow Indication
– Stainless Steel Measuring Components
– Special Alloy Material Options
– Electronic Signal Output Options
– Compact Industrial Installation
– Full-Scale Liquid Flow Rates from approximately 1.5 l/h on selected configurations
3. H250 M8 – Compact Metal Tube Variable Area Flowmeter
– H250 M8 Standard Configuration
– Mechanical Indicator
– Electronic Bargraph Indicator
– 4–20 mA Output
– HART Communication
– Liquid Flow Measurement
– Gas Flow Measurement
– Compact Process Installation
– Threaded and Flanged Connections
– Hygienic Connection Options
– DN15–25 Flanged Configurations
– Operating Temperature: -40 to +200°C
– Pressure Ratings up to 145 barg on applicable configurations
4. DK37 M8 – Advanced Low-Flow Metal Tube Flowmeter
– DK37 M8M Mechanical Version
– DK37 M8MR Remote Configuration
– Mechanical Pointer Indicator
– Electronic Flow Indicator
– 4–20 mA Output
– HART Communication
– Precision Liquid Measurement
– Low-Flow Gas Measurement
– Chemical Dosing Applications
– Analytical Process Systems
– Stainless Steel Construction
– Special Alloy Material Options
– G1/4 and 1/4 NPT Connections
– Operating Temperature: -40 to +150°C
– Pressure Ratings up to 220 barg
5. DK32 / DK34 – Low-Flow Metal Tube Flowmeters
– DK32 Standard Configuration
– DK32 Mechanical Indicator
– DK32 Electronic Indicator
– DK34 Standard Configuration
– DK34 Mechanical Indicator
– DK34 Electronic Indicator
– Low-Flow Liquid Measurement
– Low-Flow Gas Measurement
– Industrial Gas Sampling
– Purge Flow Monitoring
– Analytical Instrumentation
– Chemical Injection Systems
– Stainless Steel Measuring Components
– 4–20 mA Output Options
– HART Communication Options
– Adjustable Limit Switches
– G1/4 and 1/4 NPT Connections
– SIL 2 Suitable Versions on Selected Models
6. DK46 / DK47 / DK48 / DK800 – Glass Tube Low-Flow Flowmeters
– DK46 Basic Glass Tube Flowmeter
– DK47 Glass Tube Flowmeter
– DK48 Glass Tube Flowmeter
– DK800 Glass Tube Flowmeter
– Transparent Measuring Tube
– Direct Visual Flow Indication
– Low-Flow Liquid Measurement
– Low-Flow Gas Measurement
– Analytical Gas Sampling
– Sample Flow Monitoring
– Laboratory Applications
– Purge Flow Measurement
– Panel-Mounted Installation
– Compact Flowmeter Construction
– Borosilicate Glass Measuring Tubes
– Different Measuring Ranges and Scale Options
– SIL 2 Suitable Versions on Selected Models
7. VA40 – Basic Glass Tube Variable Area Flowmeter
– VA40 Standard Configuration
– VA40 Process Flowmeter
– Transparent Glass Measuring Tube
– Direct Visual Flow Measurement
– Liquid and Gas Measurement
– Basic Industrial Process Applications
– Laboratory and Analytical Systems
– Chemical Sampling
– Utility Flow Monitoring
– Panel and Pipeline Installation
– SIL 2 Suitable Versions
– Process Connection Options
– Full-Scale Liquid Flow Rates up to 100,000 l/h on selected configurations
8. VA45 – Low-Pressure Gas Variable Area Flowmeter
– VA45 Standard Configuration
– Glass Tube Measuring Design
– Low-Pressure Gas Measurement
– Gas Sampling Applications
– Analytical Instrumentation
– Laboratory Gas Flow Monitoring
– Industrial Gas Distribution
– Direct Visual Flow Indication
– Compact Panel Installation
– Low-Pressure Process Applications
9. K20 – Basic Water Variable Area Flowmeter
– K20 Standard Configuration
– Water Flow Measurement
– Cooling Water Monitoring
– Industrial Utility Applications
– Equipment Cooling Circuits
– Local Mechanical Flow Indication
– Compact Installation
– Water Distribution Monitoring
– OEM Equipment Integration
– Basic Process Flow Monitoring
Available Product Configurations
Measuring Tube Designs
– Metal Tube Variable Area Flowmeters
– Glass Tube Variable Area Flowmeters
– Stainless Steel Measuring Tubes
– Borosilicate Glass Measuring Tubes
– Compact Low-Flow Measuring Tubes
– PTFE-Lined Measuring Tubes
Wetted Materials
– Stainless Steel 316L
– Stainless Steel 316
– Hastelloy
– Inconel
– Monel
– Titanium
– 6Mo Stainless Steel
– PTFE Lining
– Borosilicate Glass
– Special Corrosion-Resistant Materials
Process Connections
– DIN Flanges
– ASME Flanges
– NPT Threaded Connections
– G Threaded Connections
– Hygienic Connections
– Clamp Connections
– Panel-Mounted Connections
– Compact Process Connections
Indicators & Electrical Outputs
– Mechanical Pointer Indicators
– Electronic Bargraph Indicators
– 4–20 mA Analog Outputs
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Pulse Outputs
– Integrated Totalizers
– Adjustable Limit Switches
– Continuous Float Monitoring
Safety & Certifications
– SIL 2 Suitable Versions
– SIL 2 Certified Configurations
– ATEX Explosion Protection
– IECEx Explosion Protection
– IP66 / IP68 Protection on Selected Models
– Hygienic Material Compliance on Selected Models
– FDA-Compliant Material Options
– EC 1935/2004 Material Compliance on Selected Models
Key Product Specifications
– H250 M40: DN15–150; -196 to +400°C; up to 1000 barg
– H250 M40 Low Flow: Low-flow measurement; selected ranges from 1.5 l/h
– H250 M8: DN15–25; -40 to +200°C; up to 145 barg
– DK37 M8: -40 to +150°C; up to 220 barg
– DK32 / DK34: Low-flow liquid and gas measurement
– DK46 / 47 / 48 / 800: Extremely low-flow measurement
– VA40: Glass tube; liquid and gas measurement
– VA45: Low-pressure gas measurement
– K20: Basic water flow measurement
Specifications are representative product-family data. Exact flow ranges, pressure limits, temperature limits, materials, connections and approvals vary by model and configuration. The H250 M40 maximum pressure rating is not available at every operating temperature.
Industrial Applications
– Chemical processing plants
– Petrochemical production facilities
– Oil and gas process systems
– Pharmaceutical manufacturing
– Food and beverage production
– Laboratory analytical systems
– Gas sampling installations
– Industrial purge systems
– Chemical dosing equipment
– Water treatment plants
– Cooling water systems
– Industrial gas distribution
– Compressed gas monitoring
– Boiler auxiliary systems
– Industrial equipment manufacturing
– Process skid installations
– Instrumentation and control panels
– OEM analytical equipment
– Industrial utility systems
– Safety instrumented systems
More Models & Technical Specifications
H250 M40
The H250 M40 is KROHNE’s established metal tube variable area flowmeter for industrial process and OEM applications.
Its modular construction allows users to select mechanical indicators, electronic outputs, totalizers, limit switches and digital communication modules according to their requirements.
It supports liquid and gas measurement and offers a wide selection of wetted materials, including stainless steel, Hastelloy, Inconel, Monel and titanium.
Its special installation variants also allow horizontal and descending pipeline arrangements on supported configurations.
H250 M40 Low Flow
This configuration extends the H250 M40 portfolio into smaller measuring ranges. It is suitable for low-flow process measurement, analytical applications and precision dosing where conventional larger flowmeters may not provide the required measuring range.
H250 M8
H250 M8 is a compact metal tube flowmeter for industrial liquids and gases. It combines local indication with optional electronic signal output, making it suitable for small process pipelines and equipment installations.
DK37 M8
DK37 M8 is designed for advanced low-flow liquid and gas measurement. Its robust metal construction supports higher-pressure applications, chemical dosing and analytical systems.
DK32 / DK34
DK32 and DK34 are compact metal tube instruments designed for low-flow measurement. They are suitable for gas sampling, purge systems, laboratory equipment and industrial process instrumentation.
DK46 / DK47 / DK48 / DK800
This product family covers very low flow rates of liquids and gases. Transparent measuring tubes provide direct visual indication, making these instruments useful for sample flow monitoring, analytical equipment and purge applications.
VA40 / VA45
VA40 provides a glass tube solution for basic industrial liquid and gas measurement, while VA45 is positioned for low-pressure gas applications. Both offer direct visual indication and simple mechanical operation.
K20
K20 is a basic variable area water flowmeter for utility systems, cooling circuits and OEM equipment where simple local flow monitoring is required.
Actual product selection depends on the measured medium, density, viscosity, operating pressure, temperature, flow range, measuring tube material, installation orientation and required electrical output.
For accurate product selection and replacement, please provide the complete KROHNE model number, measured medium, flow range, operating pressure, temperature, process connection and required output signal when making an inquiry.
Looking for other KROHNE variable area flowmeters, replacement floats, measuring tubes or specific accessories? Please contact our online customer service team for further assistance.