HART Communication & Multiplexers Pepperl+Fuchs Industrial Communication Supplier

Pepperl+Fuchs HART communication and multiplexer systems provide reliable digital communication between HART-compatible field instruments, distributed control systems (DCS), and asset management platforms. The product portfolio includes K-System HART multiplexers, H-System HiDMux2700 modules, HART loop converters, HART termination boards, communication interfaces, and configuration software.

Partsourcer supplies Pepperl+Fuchs HART interface solutions for process instrumentation, oil and gas facilities, chemical plants, power generation, pharmaceutical manufacturing, and industrial asset management applications.

Description

Pepperl+Fuchs HART Communication & Multiplexers

01. Product Overview

Pepperl+Fuchs HART Communication & Multiplexer systems are designed to provide digital access to HART-compatible field instruments through conventional 4–20 mA analog measurement loops.

HART (Highway Addressable Remote Transducer) is a communication protocol that allows digital information to be transmitted over traditional analog instrument wiring. It enables process automation systems to access additional device information without replacing existing analog instrumentation infrastructure.

The Pepperl+Fuchs HART Interface Solutions (HIS) portfolio includes HART multiplexers, HART loop converters, communication boards, termination boards, and configuration software.

K-System HART Multiplexers

The K-System platform uses DIN-rail mounted HART multiplexer modules.

  • KFD2-HMM-16 – HART Multiplexer Primary Module.
  • KFD0-HMS-16 – HART Multiplexer Secondary Module.

The master module supports 16 HART channels and can connect up to 15 additional secondary modules, providing communication access to as many as 256 field instrument loops.

H-System HART Multiplexers

The H-System platform uses termination-board-mounted communication modules.

  • HiDMux2700 – 32-channel HART Multiplexer.

It is designed for integration with compatible HART communication boards and customized termination boards for major DCS platforms.

HART Loop Converters

KFD2-HLC-Ex1.D is a HART loop converter designed for single-loop applications. It can retrieve up to four HART process variables (PV, SV, TV, and QV) and convert selected variables into three independent 4–20 mA analog outputs.

This allows additional digital instrument measurements to be made available to conventional analog control systems.

HART Termination Boards & Communication Accessories

Pepperl+Fuchs offers dedicated termination boards, communication boards, RS-485 interfaces, and associated accessories for connecting multiplexer modules to field instrument loops and host control systems.

Configuration & Device Management Software

HART Multiplexer DTM and PACTware provide configuration, communication, and diagnostic functions for compatible HART interface systems.

These products are widely used in process plants where operators need centralized access to field instrument configuration, status information, and predictive maintenance data.

02. Product Features

  • Digital HART Communication: Provides digital communication with compatible 4–20 mA/HART field instruments.
  • Multi-Channel Instrument Access: Supports centralized communication with multiple HART field devices through multiplexer systems.
  • K-System Master/Slave Architecture: KFD2-HMM-16 supports up to 15 KFD0-HMS-16 secondary modules.
  • High Channel Capacity: The K-System configuration supports up to 256 field instrument loops per master, while HiDMux2700 provides 32 channels.
  • H-System Integration: HiDMux2700 supports installation on compatible H-System termination boards.
  • Process Variable Conversion: KFD2-HLC-Ex1.D can retrieve PV, SV, TV, and QV and convert selected variables into three 4–20 mA outputs.
  • Asset Management Integration: Enables access to instrument information through compatible AMS platforms and PACTware.
  • Remote Instrument Diagnostics: Allows maintenance personnel to retrieve device status, diagnostic information, and configuration data.
  • RS-485 Communication: Multiplexer systems use RS-485 communication interfaces for PC and host system connections.
  • HART Protocol Compatibility: Selected multiplexer models support HART revisions 5 to 7.
  • Flexible Installation: K-System modules support DIN-rail installation, while H-System modules use compatible termination-board mounting.
  • Signal Loop Integration: Designed for integration with existing analog measurement loops.
  • Intrinsic Safety Options: Selected HART loop converter models provide certified interfaces for hazardous-area field devices.
  • Industrial Reliability: Designed for continuous operation in demanding process automation environments.

03. Available Product Series

Pepperl+Fuchs HART communication products are organized into the following major product families.

A. K-System HART Multiplexers

KFD2-HMM-16 – HART Multiplexer Primary Module

  • 16-channel HART master module.
  • Supports HART field devices using revisions 5–7.
  • Includes an integrated secondary module for the first 16 channels.
  • Supports up to 15 additional KFD0-HMS-16 secondary modules.
  • Maximum capacity: 256 field instrument loops.
  • RS-485 communication.
  • DIN-rail installation.
  • Compatible with Power Rail.

KFD0-HMS-16 – HART Multiplexer Secondary Module

  • 16-channel HART slave module.
  • Works together with KFD2-HMM-16.
  • Expands the number of connected HART field devices.
  • Connects to the master through a 14-pin flat ribbon cable.
  • Requires a compatible master and system connection arrangement.

B. H-System HART Multiplexers

HiDMux2700 – HART Multiplexer

  • 32-channel HART multiplexer.
  • HART field device input, revisions 5–7.
  • RS-485 communication.
  • Full three-port isolation.
  • Dual-capacitor isolation for individual input channels.
  • Designed for H-System termination-board installation.
  • Supports integration with compatible HART communication boards.

C. HART Loop Converters

KFD2-HLC Series

  • KFD2-HLC-Ex1.D – HART Loop Converter with three analog outputs.
  • KFD2-HLC-Ex1.D.2W – Related two-wire HART loop converter configuration, subject to ordering-code verification.
  • Single-loop HART communication.
  • Retrieval of additional HART process variables.
  • Configurable analog output conversion.
  • Suitable versions provide intrinsic safety protection.

D. HART Termination Boards

K-System Termination Boards

  • FI-PFH-NS0137-R – HART termination board for compatible K-System multiplexer installations.
  • FI-PFH-TR-AI Series – HART analog input termination board configurations.
  • FI-PFH-TR-AO Series – HART analog output termination board configurations.

H-System Termination Boards

  • HiSHPSM/32/MM-01 – 32-channel HART multiplexer termination board.
  • HiSHPSM/32/TB-02 – HART termination board for compatible H-System installations.
  • HiSHPTB Series – Customized termination boards for selected DCS platforms.
  • HiATB01-HART Series – HART communication and termination board configurations.

DCS-Specific Termination Solutions

  • Honeywell Experion and TDC 3000 HART termination boards.
  • Emerson and compatible DCS HART interface solutions.
  • Schneider Electric HART interface boards.
  • Foxboro HART termination board configurations.
  • Triconex HART termination board configurations.

Compatibility must be verified against the exact controller, I/O card, termination board, and multiplexer model.

E. HART Communication Interfaces & Accessories

  • RS-485 to USB Interface Converters.
  • HART Communication Boards.
  • HART Connection Cables.
  • HART Termination Accessories.
  • Power Supply and Connection Accessories.
  • HART Modems.
  • Viator RS-232 HART Interface.
  • Viator Bluetooth HART Interface.

F. HART Configuration Software

  • HART Multiplexer DTM – Device Type Manager for compatible HART multiplexer systems.
  • PACTware – FDT-based device configuration and management environment.
  • HART Communication Software – Configuration and diagnostic tools for supported field devices.

04. Available Models & Technical Specifications

KFD2-HMM-16 – HART Multiplexer Primary Module

  • Product Type: HART Multiplexer Master
  • System: K-System
  • Channel Configuration: 16 Channels
  • Maximum Expandable Capacity: 256 HART field devices
  • Secondary Modules: Up to 15 × KFD0-HMS-16
  • HART Compatibility: Revisions 5–7
  • Supply Voltage: 20–32 V DC
  • Typical Supply: 24 V DC
  • Maximum Power Consumption: 3 W
  • Communication Interface: RS-485, 2-wire multidrop
  • Communication Speed: 9,600 / 19,200 / 38,400 bit/s
  • Addressing: Up to 31 selectable addresses
  • Analog Connection: 26-pin flat cable
  • Master/Slave Connection: 14-pin flat cable
  • Terminating Resistance: External 230–500 Ω
  • Mounting: 35 mm DIN Rail
  • Protection Rating: IP20
  • Operating Temperature: -20 to +60 °C
  • Functional Safety: SIL 3 according to IEC/EN 61508

KFD0-HMS-16 – HART Multiplexer Secondary Module

  • Product Type: HART Multiplexer Slave
  • System: K-System
  • Channel Configuration: 16 Channels
  • HART Compatibility: Revisions 5–7
  • Communication Connection: 14-pin flat ribbon cable to KFD2-HMM-16
  • Function: Expansion of HART field device communication channels
  • Maximum Expansion: 15 secondary modules per compatible master
  • Maximum Combined Capacity: 256 HART field devices per master system
  • Mounting: Compatible K-System installation arrangement
  • Functional Safety: SIL 3 according to applicable certification

Note: KFD0-HMS-16 is a secondary module and must be used with the compatible KFD2-HMM-16 master. Verify its separate power and termination arrangements in the official documentation.

HiDMux2700 – HART Multiplexer

  • Product Type: HART Multiplexer
  • System: H-System
  • Channel Configuration: 32 Channels
  • HART Compatibility: Revisions 5–7
  • Communication Interface: RS-485
  • Supply Voltage: 20.4–30 V DC
  • Supply Arrangement: Via compatible termination board
  • Rated Current: Approximately 28 mA at 24 V DC, RS-485 quiescent condition
  • Power Dissipation: 0.7 W at 24 V DC
  • Isolation: Full three-port isolation
  • Channel Isolation: Dual-capacitor isolation per input channel
  • Mounting: H-System Termination Board
  • Functional Safety: SIL 3 according to IEC/EN 61508
  • Application: Centralized HART instrument communication and DCS integration

KFD2-HLC-Ex1.D – HART Loop Converter

  • Product Type: HART Loop Converter / Isolated Barrier
  • System: K-System
  • Channel Configuration: 1-Channel HART Input
  • HART Input: Compatible HART field transmitter
  • Measurement Variables: PV, SV, TV, QV
  • Analog Outputs: 3 × 4–20 mA
  • Output Configuration: Sink or Source
  • Output Function: Independent process variable conversion and signal splitting
  • Power Supply: 19–30 V DC
  • Power Rail: Supported
  • Configuration: Front keypad or PACTware
  • Communication: HART
  • Function: Conversion of additional HART variables into conventional analog signals
  • Application: Process control system integration and additional variable monitoring
  • Hazardous-Area Protection: Certified intrinsic safety configurations, subject to certificate conditions

The specifications above are based on representative official models. Exact product revisions, terminal arrangements, approvals, and electrical parameters must be checked against the complete manufacturer’s ordering code.

05. Industrial & Mobile Applications

Pepperl+Fuchs HART communication and multiplexer systems support various process automation and instrument management applications.

Oil & Gas Industry

  • Remote configuration of pressure transmitters
  • Flow transmitter diagnostics
  • Tank level instrument monitoring
  • Pipeline instrumentation management
  • Offshore field instrument communication
  • Predictive maintenance of process instruments

Chemical & Petrochemical Plants

  • HART-enabled temperature transmitter monitoring
  • Pressure and differential pressure transmitter configuration
  • Smart valve positioner diagnostics
  • Chemical process instrument management
  • Centralized field device parameter access
  • DCS asset management integration

Power Generation

  • Boiler instrument diagnostics
  • Turbine pressure and temperature monitoring
  • Flow transmitter parameter management
  • Smart valve diagnostics
  • Distributed process instrumentation monitoring

Pharmaceutical & Food Processing

  • Temperature transmitter configuration
  • Pressure instrument calibration support
  • Flow meter diagnostics
  • Digital instrument status monitoring
  • Process equipment maintenance

Industrial Process Automation

  • 4–20 mA/HART instrument integration
  • Multiple HART loop communication
  • Additional process variable acquisition
  • PLC and DCS interface integration
  • Centralized instrument configuration
  • HART device fault monitoring

Asset Management & Predictive Maintenance

  • Remote instrument identification
  • Device configuration and parameter access
  • Instrument status monitoring
  • HART diagnostic information retrieval
  • Preventive maintenance planning
  • Plant asset management system integration

06. More Models & Technical Specifications

Additional Pepperl+Fuchs HART communication products include:

K-System HART Multiplexers

  • KFD2-HMM-16 – 16-channel HART master.
  • KFD0-HMS-16 – 16-channel HART secondary module.
  • FI-PFH-NS0137-R – K-System HART termination board.

H-System HART Multiplexers

  • HiDMux2700 – 32-channel HART multiplexer.
  • HiSHPSM/32/MM-01 – 32-channel HART termination board.
  • HiSHPSM/32/TB-02 – H-System termination board.
  • HiATB01-HART Series – HART communication boards.

HART Loop Converters

  • KFD2-HLC-Ex1.D – Single-channel HART loop converter with three analog outputs.
  • Related KFD2-HLC configurations – Model-dependent HART variable conversion and signal splitting.

HART Communication Accessories

  • Viator RS-232 HART Interface.
  • Viator Bluetooth HART Interface.
  • HART Modems.
  • RS-485 to USB Interface Converters.
  • HART Connection Cables.
  • HART Communication Accessories.

HART Software

  • HART Multiplexer DTM.
  • PACTware.
  • Compatible FDT/DTM device management tools.

Available Technical Configurations

  • HART Communication Protocol
  • HART Revision Compatibility
  • Multiplexer System Type: K-System / H-System
  • Master / Secondary Module
  • Number of HART Channels
  • Maximum Connected Field Devices
  • Analog Loop Compatibility
  • 4–20 mA Signal Integration
  • HART Process Variables: PV / SV / TV / QV
  • Analog Output Channels
  • Output Current Range
  • Sink / Source Output Mode
  • RS-485 Communication
  • Communication Baud Rate
  • Device Address Configuration
  • Termination Resistance
  • Galvanic Isolation
  • Intrinsic Safety Protection
  • Termination Board Compatibility
  • DIN-Rail Mounting
  • Power Supply Voltage
  • Functional Safety Classification
  • SIL Certification
  • HART DTM Software Compatibility
  • PACTware Compatibility
  • Operating Temperature
  • Protection Rating

Technical specifications, communication capacity, output configurations, and hazardous-area approvals vary by model. Always verify the official product datasheet and system compatibility before selecting or replacing HART communication equipment.

Looking for additional Pepperl+Fuchs HART multiplexers, loop converters, termination boards, or communication interfaces? Contact our online customer service team for model identification and sourcing assistance.