Intrinsic Safety & Zener Barriers | Pepperl+Fuchs Explosion Protection Supplier

Pepperl+Fuchs intrinsic safety and Zener barriers provide reliable electrical protection and signal interfacing between hazardous-area field devices and safe-area control systems. The portfolio includes Z-System Zener barriers, K-System DIN-rail isolated barriers, and H-System termination-board mounted isolated barriers, supporting analog, digital, NAMUR, and process instrumentation signals.

Partsourcer supplies Pepperl+Fuchs explosion protection interface solutions for oil and gas facilities, chemical processing plants, pharmaceutical manufacturing, power generation, and industrial process automation.

Description

Pepperl+Fuchs Intrinsic Safety & Zener Barriers

01. Product Overview

Pepperl+Fuchs intrinsic safety and Zener barriers are designed to protect electrical circuits and interface field instrumentation operating in potentially explosive industrial environments.

These devices are installed between hazardous-area field equipment and safe-area control systems to limit electrical energy, provide signal isolation, and maintain the required intrinsic safety protection for compatible field circuits.

The product portfolio includes three major technology platforms:

Z-System – Zener Barriers

Zener barriers use Zener diodes, current-limiting resistors, and protective fuses to restrict the electrical energy transferred from safe areas into hazardous areas. They require a dedicated, reliable grounding connection to maintain their intrinsic safety function.

K-System – DIN-Rail Isolated Barriers

K-System isolated barriers provide galvanic isolation between field circuits and control systems. They are designed for DIN-rail mounting and offer flexible configurations for analog signals, digital signals, NAMUR sensors, temperature measurement, and process control.

Selected K-System modules use the Power Rail system to simplify power distribution and reduce wiring requirements.

H-System – Termination-Board Mounted Isolated Barriers

H-System modules are designed for installation on dedicated termination boards. They provide compact, high-density signal interfacing for distributed control systems (DCS) and safety instrumented systems (SIS).

Major product families include Z-System, KFD2, KCD2, KFD0, HiC, and associated Power Rail and termination board accessories.

These products are widely used in oil and gas, petrochemical processing, chemical plants, pharmaceutical production, and other hazardous-area process industries.

02. Product Features

  • Intrinsic Safety Protection: Limits electrical energy transferred into hazardous-area field circuits to prevent ignition under specified fault conditions.
  • Galvanic Isolation: Selected isolated barriers provide electrical separation between field circuits, control systems, and power supplies.
  • Multiple Signal Types: Supports analog input/output, digital input/output, NAMUR sensors, temperature signals, and frequency conversion.
  • Zener Barrier Technology: Z-System modules use Zener diodes, current-limiting resistors, and fuses to restrict energy transfer.
  • Flexible Installation: Zener barriers and K-System modules are available for 35 mm DIN-rail mounting.
  • Power Rail Integration: Selected K-System modules support centralized power distribution through the Power Rail system.
  • DCS & SIS Compatibility: H-System and selected K-System products support integration with industrial control and safety systems.
  • HART Compatibility: Selected isolated barriers provide transparent HART communication for smart field instruments.
  • Multiple Channel Configurations: Available single-channel, dual-channel, and other application-specific configurations.
  • Functional Safety: Selected models are certified for SIL 2 or SIL 3 applications according to their individual safety documentation.
  • International Approvals: Selected models carry ATEX, IECEx, FM, cULus, and other hazardous-area approvals.
  • Compact Modular Design: Narrow housings and termination-board solutions help optimize control cabinet space.
  • Industrial Reliability: Designed for continuous operation in demanding process automation environments.

03. Available Product Series

Pepperl+Fuchs intrinsic safety barriers are organized into the following major product families.

A. Z-System – Zener Barriers

Z-System provides passive Zener barrier solutions for different intrinsic safety circuit requirements.

Zener Barrier Series

  • Z7 Series – DC Zener barriers with positive polarity.
  • Z8 Series – DC Zener barriers with negative polarity.
  • Z9 Series – AC Zener barriers for alternating and direct voltage signals.
  • Z***.F Variants – Configurations with replaceable backup fuses.
  • Z***.CL Variants – Configurations with current-limited field circuits.
  • Z***.H Variants – High-power Zener barrier configurations.
  • Z***.R Variants – Asymmetrical Zener barrier configurations.

Available models include different voltage limits, current ratings, channel counts, polarity configurations, and intrinsic safety parameters.

B. K-System – DIN-Rail Isolated Barriers

K-System is one of Pepperl+Fuchs’ major process interface product platforms.

Analog Input & Transmitter Power Supplies

  • KFD2-STC Series – SMART transmitter power supplies and isolated analog input interfaces.
  • KFD2-SCD Series – SMART current driver and signal conditioning modules.
  • KFD2-SCS Series – SMART transmitter and valve positioner interface solutions.

Digital Input & Switch Amplifiers

  • KFD2-SR Series – Switch amplifiers for NAMUR sensors and dry contacts.
  • KFD2-SR2 Series – Single-channel and dual-channel isolated switch amplifiers.
  • KFD2-SH Series – Specialized switch amplifier configurations.

Analog & Digital Signal Interfaces

  • KCD2 Series – Compact isolated barrier and signal conditioning modules.
  • KFD0 Series – Specialized interface and isolated barrier solutions.
  • KFD2-UT Series – Temperature and universal signal interface modules.

Power Distribution

  • Power Rail – DIN-rail power distribution system for compatible K-System modules.
  • KFD2-EB2 Series – Power feed and distribution accessories.

C. H-System – Termination-Board Mounted Isolated Barriers

H-System provides isolated barrier modules for high-density control system installations.

HiC Series

  • HiC2025 – SMART transmitter power supply.
  • HiC2025A – SMART transmitter power supply variants.
  • HiC2031 – Process interface and isolated barrier modules.
  • HiC2422 – SMART transmitter power supply and current driver for valve positioner control and monitoring.
  • Additional HiC modules – Analog, digital, temperature, and specialized process signal interfaces.

H-System Accessories

  • H-System Termination Boards – Dedicated mounting and connection platforms.
  • HiCTB Series – Termination boards for compatible DCS and SIS installations.
  • H-System Power and Connection Accessories – Components for system integration.

D. Safety System & DCS Integration Solutions

Pepperl+Fuchs also offers application-specific isolated barrier platforms for major control system manufacturers.

  • Emerson DeltaV – K-System and H-System interface solutions.
  • Schneider Electric Triconex – H-System and K-System barrier platforms.
  • Yokogawa CENTUM VP – H-System interface and termination board solutions.
  • Yokogawa ProSafe-RS – Safety-related isolated barrier and termination board solutions.
  • Foxboro DCS – Customized H-System interface platforms.

Actual module compatibility depends on the selected controller, I/O card, termination board, and system configuration.

04. Available Models & Technical Specifications

Z864 – Zener Barrier

  • Product Type: Zener Barrier
  • Series: Z-System
  • Channel Configuration: 2-Channel
  • Circuit Type: DC
  • Polarity: Negative
  • Working Voltage: 10 V at 10 µA
  • Nominal Resistance: 1000 Ω
  • Series Resistance: Maximum 1033 Ω
  • Fuse Rating: 50 mA
  • Hazardous-Area Connection: Terminals 1, 2 and 3, 4
  • Safe-Area Connection: Terminals 5, 6 and 7, 8
  • Mounting: 35 mm DIN Rail
  • Connection: Screw Terminals
  • Protection Rating: IP20
  • Operating Temperature: -20 to +60 °C
  • Dimensions: 12.5 × 115 × 116 mm (W × H × D)
  • Weight: Approximately 150 g
  • Hazardous-Area Approval: ATEX and IECEx configurations, subject to certificate conditions

KFD2-STC4-Ex1 – SMART Transmitter Power Supply

  • Product Type: SMART Transmitter Power Supply
  • Series: K-System
  • Signal Type: Analog Input
  • Channel Configuration: 1-Channel
  • Hazardous-Area Input: 0/4–20 mA
  • Output Signal: 0/4–20 mA
  • Rated Supply Voltage: 20–35 V DC
  • Power Consumption: Approximately 1.9 W
  • Input Resistance: Model-dependent terminal configuration
  • Output Load: 0–800 Ω
  • Output Ripple: ≤ 50 µA RMS
  • Communication: HART-compatible signal transmission
  • Mounting: DIN Rail
  • Power Supply: Power Rail or terminals
  • Functional Safety: Up to SIL 2 for the relevant certified configuration

KFD2-SR2-Ex2.W – Two-Channel Switch Amplifier

  • Product Type: Switch Amplifier / Isolated Barrier
  • Series: K-System
  • Channel Configuration: 2-Channel
  • Input: NAMUR Sensors or Dry Contacts
  • Output: Relay Contacts
  • Power Supply: 24 V DC through Power Rail or terminals
  • Function: Reversible operating mode
  • Line Fault Detection: Available
  • Mounting: DIN Rail
  • Interface: Galvanically isolated signal interface
  • Functional Safety: Up to SIL 2 (SC 3) according to IEC/EN 61508
  • Application: Hazardous-area digital signal monitoring

HiC2025 – SMART Transmitter Power Supply

  • Product Type: SMART Transmitter Power Supply
  • Series: H-System
  • Signal Type: Analog Input
  • Channel Configuration: 1-Channel
  • Power Supply: 24 V DC through compatible system power arrangement
  • Input: Two-Wire SMART Transmitters or Current Sources
  • Output: 4–20 mA or 1–5 V, depending on configuration
  • Isolation: Galvanic isolation
  • Mounting: Compatible H-System Termination Board
  • Functional Safety: SIL 2 (SC 3), according to the applicable product documentation
  • Application: Process instrumentation and DCS integration

The technical specifications above refer to representative individual models. Verify complete ordering codes, electrical parameters, safety approvals, and compatible termination boards before selecting or replacing a module.

05. Industrial & Mobile Applications

Pepperl+Fuchs intrinsic safety and Zener barriers are widely used in hazardous-area process automation and industrial control systems.

Oil & Gas Industry

  • Pressure transmitter signal interfacing
  • Flow meter signal isolation
  • Tank level monitoring
  • Gas detection system interfaces
  • Hazardous-area valve positioner control
  • Offshore process instrumentation

Chemical & Petrochemical Processing

  • Chemical reactor instrumentation
  • Temperature transmitter interfaces
  • Pressure and flow signal conditioning
  • Hazardous-area sensor connections
  • Process control system integration
  • Explosion-protected measurement circuits

Pharmaceutical & Food Processing

  • Process temperature monitoring
  • Tank level measurement
  • Pressure transmitter integration
  • Hazardous-area equipment interfaces
  • Hygienic process instrumentation

Power Generation & Energy

  • Boiler instrumentation
  • Turbine monitoring interfaces
  • Fuel system measurement
  • Gas monitoring and process control
  • Safety instrumented system integration

Industrial Process Automation

  • PLC and DCS signal interfacing
  • Analog and digital signal isolation
  • NAMUR sensor signal processing
  • Relay output control
  • SMART transmitter communication
  • Safety-related instrumentation

Hazardous-Area Control Cabinets

  • DIN-rail isolated barrier installation
  • Zener barrier circuit protection
  • H-System termination board integration
  • Control cabinet signal distribution
  • Intrinsic safety loop protection

06. More Models & Technical Specifications

Additional Pepperl+Fuchs intrinsic safety interface products include:

Z-System

  • Z7 Series – Positive-polarity DC Zener barriers.
  • Z8 Series – Negative-polarity DC Zener barriers.
  • Z9 Series – AC Zener barriers.
  • Z864 – Two-channel DC Zener barrier, negative polarity.
  • Z964 – Two-channel AC Zener barrier.
  • Replaceable-fuse and specialized current-limiting variants.

K-System

  • KFD2-STC Series – SMART transmitter power supplies.
  • KFD2-SR Series – NAMUR switch amplifiers.
  • KFD2-SCD Series – Signal conditioning and current driver modules.
  • KCD2 Series – Compact isolated barriers and interface modules.
  • KFD0 Series – Specialized signal interface modules.
  • KFD2-UT Series – Temperature and universal signal interfaces.
  • Power Rail – Compatible power distribution accessories.

H-System

  • HiC2025 – SMART transmitter power supply.
  • HiC2025A – Transmitter power supply variant.
  • HiC2031 – Process interface module.
  • HiC2422 – SMART transmitter power supply and current driver.
  • HiCTB Series – H-System termination boards.

Available Technical Configurations

  • Barrier Technology: Zener / Galvanically Isolated
  • System Type: Z-System / K-System / H-System
  • Signal Type: Analog / Digital / NAMUR / Temperature
  • Input Signal Range
  • Output Signal Range
  • Working Voltage
  • Maximum Input Voltage
  • Current Limitation
  • Series Resistance
  • Channel Configuration
  • Isolation Voltage
  • Power Supply Voltage
  • HART Communication Compatibility
  • Relay / Transistor Outputs
  • Line Fault Detection
  • DIN-Rail Mounting
  • Termination Board Compatibility
  • Power Rail Compatibility
  • Hazardous-Area Classification
  • ATEX / IECEx / FM / cULus Approvals
  • SIL Classification
  • Operating Temperature
  • Housing Dimensions

Technical specifications and safety approvals are model-specific. Always check the official product datasheet and intrinsic safety certificate for the complete ordering code and intended hazardous-area application.