Description
Product Overview
KROHNE differential pressure (DP) flow measurement systems are designed to measure the volumetric and mass flow of liquids, gases and steam in industrial pipelines.
These systems operate by creating a controlled pressure difference across a primary flow element installed in the pipeline. The differential pressure is measured by a DP transmitter and converted into flow information using established fluid measurement principles.
The OPTIBAR product portfolio combines differential pressure transmitters, primary flow elements, calibrated meter runs, accessories and flow computers to provide complete flow measurement solutions.
The systems can be configured for standard process applications as well as demanding operating conditions involving high temperatures, high pressures, large pipe diameters, abrasive media and viscous fluids.
Product Features
– Differential pressure flow measurement technology.
– Liquid, gas and steam measurement.
– Volumetric and mass flow calculation.
– Orifice plate primary elements.
– Averaging pitot tube technology.
– Venturi and flow nozzle measurement.
– Wedge and cone flowmeter designs.
– Integrated DP transmitter solutions.
– Pressure and temperature compensation.
– 3D linearization technology on supported transmitters.
– High-pressure process applications.
– High-temperature measurement configurations.
– Low-pressure-loss measurement options.
– Large pipeline measurement capability.
– Calibrated meter run assemblies.
– Standardized designs according to ISO 5167 and applicable ASME standards.
– 4–20 mA analog output.
– HART communication.
– PROFIBUS PA.
– FOUNDATION Fieldbus.
– Bluetooth configuration on supported transmitters.
– SIL 2 / SIL 3 certified configurations.
– ATEX and IECEx explosion protection options.
– Complete engineering and documentation packages.
Product Series
1. OPTIBAR DP 3050 – Compact Differential Pressure Transmitter
– Differential Pressure Measurement
– Flow Measurement Applications
– Level Measurement Applications
– Process Pressure Measurement
– Integrated Static Pressure Measurement
– Fully Welded Stainless Steel Construction
– Total 3D Linearization
– High Measurement Stability
– Fast Response Time
– 4–20 mA Output
– HART Communication
– Ex-i Protection Options
– Oxygen Service Configuration
– Reference Accuracy ±0.1%
– Measuring Range: 100 mbar–16 bar
– Line Pressure up to 160 bar
2. OPTIBAR DP 7060 – Advanced Differential Pressure Transmitter
– Differential Pressure Measurement
– Flow Measurement
– Hydrostatic Level Measurement
– Density Measurement
– Interface Measurement
– Integrated Absolute Pressure Measurement
– High-Performance 3D Linearization
– High-Pressure Process Applications
– Fast Response Time: 125 ms
– 4–20 mA Output
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Bluetooth Configuration
– SIL 2 / SIL 3 Configurations
– ATEX / IECEx Protection Options
– Measuring Range: 30 mbar–16 bar
– Line Pressure up to 700 bar
– Reference Accuracy ±0.065%
3. OPTIBAR OP 1100 / 1110 – Orifice Plates with RF / RTJ Sealing
– OPTIBAR OP 1100 Raised Face Design
– OPTIBAR OP 1110 Ring Type Joint Design
– Differential Pressure Primary Flow Elements
– Liquid Flow Measurement
– Gas Flow Measurement
– Low-Velocity Steam Measurement
– Sharp-Edge Orifice Design
– Bidirectional Orifice Profile Options
– Stainless Steel 316L Construction
– ASME 16.36 / 16.5 / 16.47 A Compatibility
– EN ISO 5167 Design
– ASME MFC-3M Design
– Sizes: ½–24 inches
– Pressure Class up to ASME Class 2500
– Operating Temperature up to +450°C
4. OPTIBAR OP 3100 / 3200 – Orifice Plates with Flat Sealing Face
– OPTIBAR OP 3100 Orifice Plate
– OPTIBAR OP 3200 Orifice Plate
– Flat Sealing Face Design
– Corner Pressure Taps
– Liquid and Gas Measurement
– Steam Flow Measurement
– Industrial Process Applications
– Stainless Steel Construction
– Standardized Differential Pressure Measurement
– ISO 5167 Design Options
– ASME MFC-3M Design Options
– Custom Sizing and Engineering
5. OPTIBAR OP 4100 – Orifice Plate with Annular Chamber
– Integrated Annular Chamber
– Split Carrier Ring Construction
– Corner Pressure Taps
– Averaged Pressure Signal
– Stable Differential Pressure Measurement
– Industrial Liquid Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Standard Flange Installation
– Stainless Steel 316L
– Sizes: DN50–600
– Pressure Ratings up to PN100
– Operating Temperature up to +400°C
– ISO 5167 Compliance
6. OPTIBAR OP 5100 / 5110 – Orifice Plate with Measuring Flanges
– OPTIBAR OP 5100 Orifice Assembly
– OPTIBAR OP 5110 Orifice Assembly
– Integrated Measuring Flange Design
– Differential Pressure Measurement
– Liquid, Gas and Steam Applications
– High-Pressure Pipeline Measurement
– Industrial Process Instrumentation
– ASME 16.36 Compatibility
– Customized Flange Configurations
– Engineering and Calibration Options
7. OPTIBAR PT 2000 – Averaging Pitot Tube Flowmeter
– Multiple Impact-Sensing Ports
– Averaged Differential Pressure Measurement
– Low Pressure Loss Design
– Liquid Flow Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Large Pipeline Applications
– Retrofit Installation
– No Full Pipeline Cutting Required
– Compact and Separate Configurations
– Standard and Engineered Versions
– Stainless Steel 316L
– Sizes: DN50–2000
– Larger Sizes Available on Request
– Cryogenic and High-Temperature Configurations
– Operating Temperature up to +1000°C on supported designs
– Pressure Ratings up to 160 bar
8. OPTIBAR MR 2000 – Averaging Pitot Tube Meter Run
– Calibrated Meter Run Assembly
– Integrated Averaging Pitot Tube
– DP Transmitter Integration
– Liquid and Gas Measurement
– Steam Flow Measurement
– Small Pipeline Applications
– DN15–50 Nominal Sizes
– Engineered Process Connections
– Compact Installation
– Integrated Measurement Accessories
9. OPTIBAR MR 4300 – Orifice Plate Meter Run
– Integrated Orifice Plate Assembly
– Calibrated Measuring Pipe
– Differential Pressure Measurement
– Liquid and Gas Measurement
– Steam Flow Measurement
– Small Pipeline Applications
– DN15–50 Nominal Sizes
– Standardized Meter Run Design
– DP Transmitter Integration
– Process Connection Options
10. OPTIBAR MR 6300 – Cone Flowmeter Meter Run
– Integrated Cone Flow Element
– Compact Meter Run Assembly
– Differential Pressure Measurement
– Limited Installation Space Applications
– Liquid Flow Measurement
– Gas Flow Measurement
– Industrial Process Applications
– Calibrated Metering Configurations
– DN100–600 Typical Product Range
– Customized Engineering Options
11. Compact Orifice Plate Flowmeter
– Integrated Orifice Flow Measurement
– Differential Pressure Transmitter Integration
– Liquid, Gas and Steam Measurement
– Compact Pipeline Installation
– Reduced Installation Requirements
– Pressure and Temperature Compensation Options
– High-Temperature Process Applications
– DN50–600 Line Sizes
– Operating Temperature up to +400°C
– Line Pressure up to 160 bar
– HART / PROFIBUS PA / FOUNDATION Fieldbus Options
12. Integral DP Flowmeter
– Integrated Differential Pressure Measuring Assembly
– Primary Flow Element and DP Transmitter Combination
– Liquid Flow Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Compact Installation
– No Separate Impulse Lines Required
– Reduced Engineering Requirements
– Pressure and Temperature Compensation
– High-Temperature Applications
– DN50–600 Line Sizes
– Operating Temperature up to +400°C
– Line Pressure up to 160 bar
13. Integral Orifice Meter Run Assembly
– Standardized Calibrated Meter Run
– Integrated Orifice Plate
– DP Transmitter Integration
– Manifold and Accessories
– Liquid and Gas Measurement
– Viscous Fluid Applications
– Fluids with Suspended Solids
– Gas-Entrained Liquid Measurement
– ISO 5167 / ISO TR 15377 Design
– DN15–100 Flanged Connections
– Operating Temperature up to +400°C
– Line Pressure up to 160 bar
– HART / PROFIBUS PA / FOUNDATION Fieldbus
– Redundant Measurement Configurations
14. Venturi Flowmeter – Differential Pressure Flow Element
– Venturi Tube Flow Measurement
– Differential Pressure Measurement
– Liquid Flow Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Low Pressure Loss Design
– Stable Long-Term Measurement
– Large Pipeline Applications
– Industrial Process Measurement
– ISO and ASME Standard Design Options
– Customized Material and Connection Options
15. Flow Nozzle Meter – Differential Pressure Flow Element
– Flow Nozzle Primary Element
– Differential Pressure Flow Measurement
– Liquid and Gas Measurement
– Steam Flow Measurement
– High-Velocity Flow Applications
– High-Temperature Process Measurement
– Power Plant Applications
– Boiler Feedwater Measurement
– Industrial Energy Systems
– Standardized Engineering Options
16. Wedge / Cone Flowmeters – Specialized DP Flow Elements
– Wedge Flowmeter
– Cone Flowmeter
– Abrasive Fluid Measurement
– High-Viscosity Liquid Measurement
– Slurry Flow Measurement
– Suspended Solids Applications
– Limited Installation Space Solutions
– Oil and Gas Process Applications
– Refinery Residue Measurement
– Low Straight-Pipe Requirement on Supported Designs
– Stainless Steel and Special Alloy Materials
– Customized Industrial Engineering
Available Product Configurations
Primary Flow Elements
– RF Orifice Plates
– RTJ Orifice Plates
– Flat Sealing Orifice Plates
– Annular Chamber Orifice Plates
– Measuring Flange Assemblies
– Averaging Pitot Tubes
– Venturi Tubes
– Flow Nozzles
– Wedge Flow Elements
– Cone Flow Elements
Differential Pressure Transmitters
– OPTIBAR DP 3050
– OPTIBAR DP 7060
– Integrated Absolute Pressure Measurement
– Pressure and Temperature Compensation
– Compact and High-Performance Versions
– Remote Configuration Options
Meter Run Assemblies
– OPTIBAR MR 2000
– OPTIBAR MR 4300
– OPTIBAR MR 6300
– Integral Orifice Meter Run
– Calibrated Meter Runs
– Engineered Pipeline Assemblies
Process Media
– Water
– Wastewater
– Crude Oil
– Refined Petroleum Products
– Natural Gas
– Industrial Gases
– Steam
– Superheated Steam
– Thermal Oil
– Viscous Liquids
– Abrasive Slurries
– Fluids Containing Suspended Solids
Electrical & Communication
– 4–20 mA Analog Output
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Bluetooth Configuration
– Flow Computation
– Pressure Compensation
– Temperature Compensation
– Integrated Diagnostics
– Flow Totalization
Safety & Certifications
– SIL 2 / SIL 3 Configurations
– ATEX Explosion Protection
– IECEx Explosion Protection
– PED 2014/68/EU
– CE Marking
– ISO 5167 Design
– ASME MFC-3M Design
– AGA 3 Design Options
– GOST 8.586 Design Options
Key Product Specifications
– OPTIBAR DP 3050: 100 mbar–16 bar; line pressure up to 160 bar
– OPTIBAR DP 7060: 30 mbar–16 bar; line pressure up to 700 bar
– OPTIBAR OP 1100: ½–24 inches; up to ASME Class 2500
– OPTIBAR OP 4100: DN50–600; up to PN100
– OPTIBAR PT 2000: DN50–2000; low pressure loss
– OPTIBAR MR 2000: DN15–50; averaging pitot tube
– OPTIBAR MR 4300: DN15–50; orifice plate
– OPTIBAR MR 6300: Cone flowmeter assembly
– Integral Orifice Meter Run: DN15–100; up to +400°C
– Compact Orifice Flowmeter: DN50–600; up to +400°C
– Wedge Flowmeter: DN50–600; up to +500°C
– Cone Flowmeter: DN50–600 standard ISO 5167-5 sizes
Specifications are based on available KROHNE product-family information. Actual performance depends on pressure class, material, fluid properties, line size, primary element geometry and transmitter configuration. The maximum temperature and pressure ratings are not necessarily simultaneously available.
Industrial Applications
– Oil and gas production facilities
– Natural gas transmission pipelines
– Petroleum refineries
– Petrochemical plants
– Chemical processing facilities
– Power generation plants
– Steam distribution networks
– Boiler and feedwater systems
– Industrial heating systems
– Large water pipelines
– Wastewater treatment facilities
– Industrial gas distribution
– High-pressure process pipelines
– High-temperature process systems
– Heavy oil measurement
– Refinery residue measurement
– Slurry and abrasive fluid measurement
– Industrial energy management
– Pipeline retrofit projects
– Process engineering and EPC projects
More Models & Technical Specifications
OPTIBAR DP 3050
OPTIBAR DP 3050 is a compact differential pressure transmitter for general pressure, level and flow applications.
Its fully welded stainless steel construction and integrated static pressure measurement make it suitable for industrial process applications requiring stable and accurate differential pressure measurement.
OPTIBAR DP 7060
OPTIBAR DP 7060 is a high-performance differential pressure transmitter with integrated absolute pressure measurement.
It can be combined with orifice plates and pitot tubes to create complete DP flow measurement systems. Its modular design also supports hydrostatic level, density and interface measurement applications.
OPTIBAR OP Series
The OPTIBAR OP family covers several orifice plate designs for different pipeline configurations and pressure measurement requirements.
OP 1100 and OP 1110 provide raised face and RTJ sealing configurations. OP 3100 and OP 3200 use flat sealing faces and corner taps, while OP 4100 incorporates an annular chamber for pressure averaging.
OP 5100 and OP 5110 provide measuring flange assemblies for industrial differential pressure measurement.
OPTIBAR PT 2000
OPTIBAR PT 2000 is an averaging pitot tube with multiple impact-sensing ports across the pipeline diameter.
It is particularly useful for large pipelines, low-pressure-loss measurement and retrofit applications where installing a conventional orifice plate would create excessive pressure loss.
OPTIBAR MR Series
The MR series provides calibrated meter run assemblies with integrated primary flow elements.
MR 2000 combines an averaging pitot tube, MR 4300 uses an orifice plate, and MR 6300 incorporates a cone flow element.
These solutions simplify engineering, installation and commissioning for small and medium-sized pipeline applications.
Complete Differential Pressure Flow Measurement Systems
KROHNE provides complete measurement assemblies combining primary elements, differential pressure transmitters, manifolds, valves, accessories, engineering, calibration and documentation.
Depending on the application, these assemblies can be supplied as ready-to-install measurement solutions for liquids, gases and steam.
Actual product selection depends on measured medium, pipe diameter, flow range, density, viscosity, pressure, temperature, allowable pressure loss, installation conditions and required measurement accuracy.
For accurate product selection and replacement, please provide the complete KROHNE model number, measured medium, pipeline diameter, operating pressure, temperature, flow range and required communication interface when making an inquiry.
Looking for other KROHNE differential pressure transmitters, orifice plates, pitot tubes, meter runs or complete flow measurement assemblies? Please contact our online customer service team for further assistance.