KROHNE differential pressure flow measurement systems are designed for accurate measurement of liquid, gas, and steam flow in industrial process applications. The product portfolio includes OPTIBAR DP 3050 and DP 7060 differential pressure transmitters, OPTIBAR OP orifice plates, PT 2000 averaging pitot tubes, compact orifice plate flowmeters, and engineered primary flow elements such as Venturi tubes, flow nozzles, wedge meters, and cone meters. These solutions support pressure differential measurement, flow calculation, process monitoring, and energy management in demanding industrial environments.

Description

Product Overview

KROHNE differential pressure flow measurement systems provide reliable measurement solutions for liquids, gases, and steam in industrial process applications.

The differential pressure measuring principle is based on creating a pressure difference across a primary flow element installed in the pipeline. The differential pressure transmitter measures this pressure difference and converts it into a signal for calculating flow rate.

KROHNE offers a complete range of differential pressure measurement components, including differential pressure transmitters, orifice plates, averaging pitot tubes, compact orifice flowmeters, and engineered primary flow elements.

The OPTIBAR DP 3050 and OPTIBAR DP 7060 provide differential pressure measurement for flow, level, and other process applications. When combined with suitable primary elements, they form complete differential pressure flow measurement systems.

Product Features
– Differential pressure-based flow measurement.
– Suitable for liquids, gases, and steam.
– Multiple primary flow element designs.
– Orifice plate and averaging pitot tube solutions.
– Integrated and remote transmitter configurations.
– High-pressure process measurement options.
– High-temperature measurement applications.
– Integrated static pressure measurement on selected transmitters.
– Advanced 3D linearization technology.
– Flow calculation and process compensation.
– 4–20 mA analog output.
– HART communication.
– PROFIBUS PA and FOUNDATION Fieldbus on supported models.
– SIL 2/3 certified configurations on selected products.
– ATEX and IECEx options on supported configurations.
– Engineered measurement assemblies with sizing and documentation.

Product Series

1. OPTIBAR DP 3050 – Compact Differential Pressure Transmitter
– General Differential Pressure Measurement
– Industrial Flow Measurement
– Hydrostatic Level Measurement
– Process Pressure Monitoring
– Integrated Static Pressure Measurement
– Total 3D Linearization
– 4–20 mA Output
– HART 7 Communication
– Compact Stainless Steel Construction
– Explosion Protection Options

2. OPTIBAR DP 7060 – Advanced Differential Pressure Transmitter
– High-Performance Differential Pressure Measurement
– Flow Measurement Applications
– Hydrostatic Level Measurement
– Density Measurement
– Interface Measurement
– Integrated Absolute Pressure Measurement
– Total 3D Linearization
– 4–20 mA Output
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Bluetooth Connectivity
– SIL 2/3 Configurations

3. Compact Orifice Plate Flowmeter – Integrated DP Flowmeter
– Integral Orifice Plate Assembly
– OPTIBAR DP 7060 Transmitter Integration
– Liquid Flow Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Standardized ISO 5167-2 Design
– Preassembled Meter Body
– Integrated Manifold and Impulse Connections
– Pressure-Tested Assembly
– Redundant Measurement Configurations
– HART / PROFIBUS PA / FOUNDATION Fieldbus

4. Integral Orifice Meter Run Assembly – Small Pipeline Flowmeter
– Small Pipeline Flow Measurement
– Standardized Calibrated Orifice Assembly
– DN15–100 Configurations
– Gas and Liquid Measurement
– Viscous Fluid Measurement
– Suspended Solid Applications
– Gas-Entrained Liquid Measurement
– Integrated DP Transmitter Options
– Meter Run and Manifold Assembly
– Engineering and Calibration Documentation

5. OPTIBAR OP 1100 – Orifice Plate with RF Sealing Face
– Raised Face Orifice Plate
– ASME Flange Installation
– Liquid Flow Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Stainless Steel Construction
– Differential Pressure Flow Measurement
– High-Pressure Pipeline Applications
– Standardized Orifice Plate Design

6. OPTIBAR OP 1110 – Orifice Plate with RTJ Sealing Face
– Ring Type Joint Sealing Face
– High-Pressure Flange Applications
– Oil and Gas Pipeline Measurement
– Chemical Process Applications
– Liquid and Gas Flow Measurement
– RTJ Flange Compatibility
– Industrial Differential Pressure Measurement

7. OPTIBAR OP 3100 – Orifice Plate with Flat Sealing Face
– Flat Sealing Face Design
– Corner Pressure Taps
– Standardized Orifice Plate Construction
– Liquid Flow Measurement
– Gas Flow Measurement
– Steam Flow Measurement
– Industrial Pipeline Applications

8. OPTIBAR OP 3200 – Orifice Plate with Flat Sealing Face
– Flat Sealing Face Design
– Corner Tap Configuration
– Industrial DP Flow Measurement
– Gas and Liquid Applications
– Steam Measurement
– Process Pipeline Installation
– Customized Material Options

9. OPTIBAR OP 4100 – Orifice Plate with Annular Chamber
– Annular Chamber Design
– Corner Pressure Taps
– Differential Pressure Measurement
– Industrial Process Flow Measurement
– Liquid and Gas Applications
– Steam Flow Measurement
– Pipeline Metering Applications

10. OPTIBAR OP 5100 / OP 5110 – Orifice Plate Assemblies
– Orifice Plate Assembly with Measuring Flanges
– ASME 16.36 Design
– Integrated Flange Connections
– Differential Pressure Measurement
– Industrial Gas Flow Measurement
– Liquid Flow Measurement
– Steam Measurement
– High-Pressure Process Applications

11. OPTIBAR PT 2000 – Averaging Pitot Tube Flowmeter
– Averaging Pitot Tube Design
– Multiple Impact-Sensing Ports
– Gas Flow Measurement
– Liquid Flow Measurement
– Steam Flow Measurement
– Large Pipeline Applications
– High-Temperature Gas Applications
– Dust-Laden Gas Measurement
– Differential Pressure Measurement
– Flow Measurement in Utility Systems

12. Engineered Primary Flow Elements – Special Flow Measurement Solutions
– Venturi Flowmeters
– Flow Nozzle Meters
– Wedge Flowmeters
– Cone Flowmeters
– Engineered Orifice Assemblies
– Customized Pipeline Measurement Solutions
– Abrasive Fluid Measurement
– Viscous Fluid Measurement
– Limited Installation Space Applications
– High-Temperature Process Applications

Available Product Configurations

Differential Pressure Transmitters
– Compact Differential Pressure Transmitters
– Advanced Process Differential Pressure Transmitters
– Integrated Static Pressure Measurement
– Integrated Absolute Pressure Measurement
– Electronic Signal Conversion
– Remote and Direct Mounting
– Diaphragm Seal Configurations
– High-Pressure Process Connections

Primary Flow Elements
– Orifice Plates
– Averaging Pitot Tubes
– Venturi Tubes
– Flow Nozzles
– Wedge Flowmeters
– Cone Flowmeters
– Integral Orifice Meter Runs
– Compact Orifice Assemblies

Process Connections & Materials
– Raised Face (RF) Flanges
– Ring Type Joint (RTJ) Flanges
– ASME Flange Connections
– ANSI Flange Standards
– Stainless Steel 316 / 316L
– Special Alloy Materials on Request
– Customized Pressure Ratings
– Engineered Metering Assemblies

Electrical & Communication
– 4–20 mA Analog Output
– HART Communication
– PROFIBUS PA
– FOUNDATION Fieldbus
– Bluetooth Connectivity on Supported Models
– Digital Diagnostics
– Process Control System Integration

Key Product Specifications
– OPTIBAR DP 3050: 100 mbar–16 bar; line pressure up to 160 bar
– OPTIBAR DP 7060: 30 mbar–16 bar; line pressure up to 700 bar
– Compact Orifice Plate: DN50–600; up to +400°C; 160 bar line pressure
– Integral Orifice Meter Run: DN15–100; up to +400°C; 160 bar line pressure
– OPTIBAR OP 1100: ½–24 inches; up to ASME Class 2500
– OPTIBAR OP 1110: RTJ flange design
– OPTIBAR OP 3100 / 3200: Flat sealing face; corner taps
– OPTIBAR OP 4100: Annular chamber; corner taps
– OPTIBAR OP 5100 / 5110: Measuring flange assemblies
– OPTIBAR PT 2000: Multiple impact-sensing ports

Specifications are based on KROHNE product documentation. Actual limits depend on the selected transmitter, primary element, materials, flange standards and process conditions.

Industrial Applications
– Oil and gas production facilities
– Natural gas transmission pipelines
– Petrochemical processing plants
– Chemical manufacturing facilities
– Power generation stations
– Industrial steam distribution
– Boiler and feedwater systems
– Industrial compressed air networks
– Water treatment facilities
– Wastewater treatment plants
– Refinery process monitoring
– High-temperature gas measurement
– Industrial energy management
– Process allocation measurement
– Industrial utility systems
– Automated manufacturing facilities

More Models & Technical Specifications

OPTIBAR DP 3050 is a compact differential pressure transmitter designed for general flow, level and differential pressure applications. It features fully welded stainless steel construction and integrated static pressure measurement. Its compact design makes it suitable for industrial process installations.

OPTIBAR DP 7060 is an advanced differential pressure transmitter with integrated absolute pressure measurement. It supports demanding applications involving flow, hydrostatic level, density and interface measurement. Its measuring range extends from 30 mbar to 16 bar, with line pressure up to 700 bar depending on configuration.

OPTIBAR OP 1100 and OP 1110 are primary orifice plates designed for different flange sealing arrangements. The OP 1100 uses a raised face design, while the OP 1110 uses a ring type joint sealing face for compatible high-pressure flange installations.

OPTIBAR OP 3100 and OP 3200 use flat sealing face designs with corner pressure taps. OPTIBAR OP 4100 uses an annular chamber arrangement, while OP 5100 and OP 5110 are supplied as measuring flange assemblies.

OPTIBAR PT 2000 is an averaging pitot tube with multiple impact-sensing ports. It is designed for measuring liquids, gases and steam, including large pipeline and selected high-temperature gas applications.

The compact orifice plate flowmeter integrates an orifice plate, meter body, manifold and differential pressure transmitter into a preassembled measurement solution. It is designed to reduce installation work and eliminate separate external impulse line routing.

The integral orifice meter run assembly is particularly suitable for small pipeline diameters, where upstream and downstream pipe geometry can have a significant influence on measurement accuracy.

KROHNE also offers engineered primary flow elements such as Venturi tubes, flow nozzles, wedge meters and cone meters. These are selected and designed according to the specific process requirements.

Actual product selection depends on the measured medium, flow range, operating pressure, temperature, pipeline diameter, flange standard, material requirements, pressure loss limitations and required measurement accuracy.

For accurate product selection and replacement, please provide the complete KROHNE model number, pipeline size, measured medium, operating pressure, temperature, flange standard and existing equipment details when making an inquiry.

Looking for other KROHNE differential pressure instruments, orifice plates, pitot tubes, or engineered flow elements? Please contact our online customer service team for further assistance.