KROHNE electromagnetic flowmeters are designed for accurate and reliable measurement of conductive liquids in industrial process, water treatment, chemical, and hygienic applications. The product range includes OPTIFLUX, WATERFLUX, TIDALFLUX, POWERFLUX, AF-E, FLEXMAG, and ENVIROMAG series, offering solutions for water and wastewater management, aggressive and abrasive fluids, dosing systems, custody transfer, and advanced industrial flow measurement. Available configurations include compact and remote designs, multiple liner and electrode materials, and various communication interfaces for industrial automation systems.

Description

Product Overview

KROHNE electromagnetic flowmeters are engineered to measure the volumetric flow rate of electrically conductive liquids using the principle of electromagnetic induction.

Unlike mechanical flowmeters, electromagnetic flowmeters have no moving parts in the measuring tube, reducing mechanical wear and maintenance requirements. They are suitable for a wide range of industrial applications involving water, wastewater, chemicals, slurries, and other conductive liquids.

KROHNE offers a comprehensive portfolio of electromagnetic flowmeters designed for different operating conditions, from basic utility measurement to demanding industrial processes, hygienic production, custody transfer, and safety-related applications.

The product portfolio includes compact and remote-mounted configurations, different sensor materials, liner technologies, electrode designs, and signal converter options.

Product Features
– Electromagnetic measurement technology based on Faraday’s law.
– No moving parts in the measuring tube.
– Suitable for electrically conductive liquids.
– High measurement accuracy and repeatability.
– Low pressure loss through the measuring tube.
– Multiple nominal diameters and connection standards.
– Different liner materials for chemical compatibility.
– Stainless steel and special alloy electrode options.
– Compact and remote transmitter configurations.
– Digital signal processing and diagnostic functions.
– HART, Modbus, PROFIBUS and other communication options depending on model.
– Solutions for water, wastewater, chemicals and abrasive liquids.
– Hygienic configurations for food and beverage production.
– Selected models certified for custody transfer and safety applications.

Product Series

OPTIFLUX Series – Industrial Electromagnetic Flowmeters
– OPTIFLUX 1050
– OPTIFLUX 1100
– OPTIFLUX 1300
– OPTIFLUX 1400
– OPTIFLUX 2050
– OPTIFLUX 2100
– OPTIFLUX 2300
– OPTIFLUX 2400
– OPTIFLUX 4050
– OPTIFLUX 4100
– OPTIFLUX 4300
– OPTIFLUX 4400
– OPTIFLUX 5050
– OPTIFLUX 5100
– OPTIFLUX 5300
– OPTIFLUX 5400
– OPTIFLUX 6400

WATERFLUX Series
– WATERFLUX 3050
– WATERFLUX 3070
– WATERFLUX 3100
– WATERFLUX 3300
– WATERFLUX 3400
– Potable Water Measurement Configurations
– Raw Water Measurement Configurations
– Water Distribution Network Measurement
– Irrigation Water Measurement
– Custody Transfer Water Metering

TIDALFLUX Series
– TIDALFLUX 2300
– Integrated Capacitive Level Measurement
– Wastewater Flow Measurement
– Sewer Pipeline Measurement
– Partially Filled Pipe Monitoring
– Open Channel Alternative Flow Measurement

POWERFLUX Series
– POWERFLUX 4030
– POWERFLUX 4300
– POWERFLUX 5030
– POWERFLUX 5300
– Nuclear Industry Flow Measurement
– Safety-Related Process Measurement Configurations

AF-E Series
– AF-E 400
– Industrial Utility Flow Measurement
– Cooling Water Measurement
– Heating and Cooling Circuit Measurement
– Industrial Automation Applications
– Compact Parallel Installation Configurations

FLEXMAG Series
– FLEXMAG 4050
– Biopharmaceutical Flow Measurement
– Disposable Flow Sensor Configurations
– Single-Use Process Skids
– Pharmaceutical Fluid Measurement

ENVIROMAG Series
– ENVIROMAG Electromagnetic Flowmeter
– Water Treatment Applications
– Wastewater Treatment Applications
– Industrial Water Distribution
– Municipal Water Measurement

Available Product Configurations

Industrial Flow Measurement
– Basic and Advanced Electromagnetic Measurement
– Compact Flowmeter Designs
– Remote Transmitter Configurations
– Wafer and Flanged Connections
– Different Nominal Diameters
– Multiple Operating Pressure Ratings
– Different Liner and Electrode Materials
– Digital and Analog Signal Outputs

Water & Wastewater Measurement
– Potable Water Flow Measurement
– Raw Water Measurement
– Wastewater and Sewage Measurement
– Irrigation Water Measurement
– Water Distribution Network Monitoring
– Partially Filled Pipe Measurement
– Custody Transfer Configurations

Chemical & Industrial Applications
– Corrosive Liquid Measurement
– Abrasive Slurry Measurement
– Chemical Dosing Applications
– High-Solid-Content Liquid Measurement
– Industrial Process Flow Monitoring
– High-Temperature Liquid Applications

Hygienic Applications
– Food and Beverage Flow Measurement
– Dairy Processing
– Pharmaceutical Production
– Hygienic Process Connections
– CIP and SIP Compatible Configurations
– Sanitary Measurement Applications

Electronics & Communication
– 4–20 mA Analog Outputs
– Pulse and Frequency Outputs
– HART Communication
– Modbus Communication
– PROFIBUS PA / DP
– FOUNDATION Fieldbus
– PROFINET
– IO-Link on supported models
– Bluetooth Parameterization on selected newer models

Key Product Specifications
– OPTIFLUX 1050: DN10–150; up to PN40
– OPTIFLUX 1100: DN10–150; up to PN40
– OPTIFLUX 1300: DN10–150; up to PN40
– OPTIFLUX 2300: DN25–3000; up to PN40
– OPTIFLUX 4400: Up to DN3000; up to PN40, higher on request
– OPTIFLUX 5400: DN15–300; up to PN40
– OPTIFLUX 6400: DN2.5–150; hygienic design
– WATERFLUX 3400: DN25–600; up to PN16
– TIDALFLUX 2300: DN200–1600

Specifications are based on individual KROHNE official product pages. Pressure ratings, temperature ranges, accuracy, liner materials and connection standards vary by model and configuration. Do not treat the listed nominal pressure as applicable to every meter size.

Industrial Applications
– Municipal water treatment plants
– Wastewater treatment facilities
– Drinking water distribution networks
– Chemical processing plants
– Petrochemical production facilities
– Oil and gas processing
– Food and beverage manufacturing
– Pharmaceutical production
– Pulp and paper industries
– Mining and mineral processing
– Power generation facilities
– Industrial cooling water systems
– Irrigation and agricultural water systems
– Industrial dosing and batching systems
– Marine and offshore process systems

More Models & Technical Specifications

The OPTIFLUX series covers a broad range of industrial electromagnetic flow measurement applications. OPTIFLUX 1050 and 1100 are designed for basic and general-purpose conductive liquid measurement, while OPTIFLUX 1300 is suitable for OEM applications, dosing systems, and compact skids.

OPTIFLUX 2050 and 2100 are designed for basic and standard water and wastewater applications. OPTIFLUX 2300 and the newer OPTIFLUX 2400 provide advanced water measurement solutions.

OPTIFLUX 4100 and 4300 are designed for demanding industrial processes involving abrasive and aggressive liquids. OPTIFLUX 4400 supports safety-related applications, while OPTIFLUX 5400 is intended for advanced process applications and master metering.

OPTIFLUX 6400 is designed for hygienic applications in food and beverage production, including precise flow measurement and dosing.

WATERFLUX flowmeters are specifically designed for water measurement. Their applications include drinking water distribution, raw water measurement, irrigation systems, and water network management. The WATERFLUX 3400 supports advanced water measurement applications without requiring conventional straight inlet and outlet pipe runs under its specified installation conditions.

TIDALFLUX 2300 combines electromagnetic flow measurement with integrated capacitive level measurement for partially filled pipelines, making it suitable for wastewater and sewer applications.

POWERFLUX products cover specialized nuclear industry flow measurement requirements. FLEXMAG 4050 provides single-use flow measurement for biopharmaceutical processes.

Actual product selection depends on liquid conductivity, flow velocity, nominal diameter, operating pressure, temperature, liner material, electrode material, process connection, installation conditions, and required communication protocol.

For accurate product selection and replacement, please provide the complete KROHNE model number, nominal diameter, measuring range, process pressure, temperature, liquid type, liner material, electrode material, or existing equipment details when making an inquiry.

Looking for other models, replacement sensors, or specific part numbers? Please contact our online customer service team for further assistance.