TURCK Interface Technology & Signal Conditioners Industrial Signal Isolation

TURCK Interface Technology and Signal Conditioners provide reliable signal isolation, conversion, conditioning, and intrinsic safety solutions for industrial automation and process control systems. The portfolio includes IM12 and IMX12 signal isolators, IMXK12 compact interface devices, IM33/IM34 temperature measuring amplifiers, IMC signal conditioners, and MK/MS level controllers. Available configurations support analog and digital signal processing, HART-transparent transmission, temperature measurement, and hazardous-area protection. Partsourcer supports global buyers with TURCK interface modules and signal conditioning equipment sourcing.

Description

01. Product Overview

TURCK Interface Technology and Signal Conditioners are designed to provide reliable electrical isolation, signal conversion, signal conditioning, and intrinsic safety protection for industrial automation and process control systems.

These devices form an important interface between field instruments, sensors, actuators, and higher-level control equipment, helping ensure reliable signal transmission and electrical separation between different circuit sections.

The product portfolio includes signal isolators, safety barriers, temperature measuring amplifiers, isolated switching amplifiers, analog signal conditioners, and control cabinet monitoring devices.

TURCK offers several product families, including IM12, IMX12, IMXK12, IM18, IMX18, IM33, IM34, and IMC series, covering standard industrial and hazardous-area applications.

Depending on the model, these devices support analog and digital signals, HART-transparent transmission, temperature sensor inputs, relay outputs, and different power supply configurations.

TURCK interface products are widely used in chemical processing, oil and gas facilities, pharmaceutical manufacturing, energy systems, and industrial control cabinets where reliable signal processing and electrical isolation are essential.

02. Product Features

  • Galvanic Signal Isolation: Provides electrical separation between field circuits and control systems.
  • Intrinsic Safety Protection: Selected safety barriers and isolators support intrinsically safe circuits in hazardous environments.
  • Analog Signal Conditioning: Supports isolation, conversion, and adjustment of analog measurement signals.
  • Digital Signal Processing: Available digital input and switching signal isolation configurations.
  • Temperature Measurement: Specialized measuring amplifiers support compatible RTD and thermocouple sensors.
  • HART Transparency: Selected isolating transducers preserve HART communication for intelligent field instruments.
  • Multi-Channel Configurations: Available single-channel and multi-channel devices.
  • DIN Rail Installation: Compact modules designed for industrial control cabinet mounting.
  • Flexible Power Supply: Different 24 VDC and wide-range supply configurations.
  • Hazardous-Area Approvals: Selected products carry ATEX, IECEx, cULus, and other regional certifications.
  • Relay and Transistor Outputs: Available output configurations depend on the device type.
  • Control Cabinet Monitoring: Specialized devices monitor temperature, humidity, and operating conditions inside electrical cabinets.

03. Available Product Series

1. IM12 Series – Industrial Signal Conditioners

IM12 products provide signal isolation and conditioning solutions for standard industrial control applications.

Key characteristics:

  • Analog signal isolation
  • Isolating transducers
  • Temperature measuring amplifiers
  • HART-transparent signal transmission
  • Single-channel and dual-channel configurations
  • DIN rail mounting
  • 24 VDC power supply variants
  • Selected ATEX and cULus approvals

Typical applications:

  • Analog sensor signal isolation
  • PLC analog input protection
  • Temperature measurement
  • Industrial process instrumentation

2. IMX12 Series – Intrinsically Safe Interface Modules

IMX12 products are designed for signal isolation and intrinsically safe applications involving hazardous areas.

Key characteristics:

  • Intrinsic safety protection
  • Analog signal isolation
  • Temperature measurement
  • Isolating transducer configurations
  • HART-transparent communication on selected models
  • Different channel and output configurations
  • ATEX and IECEx certified variants

Typical applications:

  • Chemical process instrumentation
  • Oil and gas measurement systems
  • Hazardous-area temperature monitoring
  • Ex-zone field instrument interfaces

3. IMXK12 Series – Compact Intrinsically Safe Interfaces

IMXK12 is a compact interface product family designed to provide isolation and signal processing in space-constrained control cabinets.

Key characteristics:

  • Compact DIN rail-mounted design
  • Intrinsically safe interface configurations
  • Analog input and output isolation
  • Digital switching signal isolation
  • HART-transparent variants
  • 24 VDC supply configurations
  • Selected ATEX, IECEx, and cULus approvals

Typical applications:

  • Compact control cabinets
  • Distributed process instrumentation
  • Hazardous-area signal interfaces
  • Industrial measurement systems

4. IM18 Series – Multi-Channel Interface Modules

IM18 products provide multi-channel isolation and switching amplification for industrial digital signal applications.

Key characteristics:

  • Multi-channel switching amplifiers
  • Digital input isolation
  • Relay and transistor output configurations
  • Compact industrial cabinet installation
  • 24 VDC power supply options
  • Selected multi-channel configurations

Typical applications:

  • Digital sensor signal isolation
  • Industrial switching circuits
  • Control system signal interfaces
  • Machine and process automation

5. IMX18 Series – Intrinsically Safe Multi-Channel Interfaces

IMX18 products provide multi-channel signal isolation and switching amplification for applications requiring hazardous-area protection.

Key characteristics:

  • Intrinsically safe signal interfaces
  • Multi-channel switching amplification
  • Digital input configurations
  • Relay and transistor outputs
  • ATEX and IECEx approved variants
  • DIN rail mounting

Typical applications:

  • Hazardous-area digital instrumentation
  • Process control systems
  • Chemical and petrochemical facilities
  • Industrial safety-related signal interfaces

6. IM33 Series – Isolating Transducers

IM33 devices are designed to isolate and transmit analog measurement signals between field instruments and control systems.

Key characteristics:

  • Analog signal isolation
  • HART-transparent configurations
  • Different input and output arrangements
  • Single-channel designs
  • Industrial process signal conditioning
  • Selected hazardous-area approvals

Typical applications:

  • 4–20 mA transmitter signal isolation
  • Pressure and flow instrument interfaces
  • Process measurement transmission
  • Analog PLC signal integration

7. IM34 Series – Temperature Measuring Amplifiers

IM34 devices provide temperature measurement and signal conditioning for compatible temperature sensors.

Key characteristics:

  • RTD and thermocouple input configurations
  • Temperature signal conversion
  • Analog output options
  • Different input and output arrangements
  • Industrial DIN rail installation
  • Selected ATEX, IECEx, and other approvals

Typical applications:

  • Industrial temperature monitoring
  • Process temperature measurement
  • Furnace and heating system monitoring
  • Temperature sensor integration with PLC systems

8. IMC Series – Compact Signal Isolation and Conversion

IMC products provide compact signal isolation and conversion solutions for selected industrial and hazardous-area applications.

Key characteristics:

  • Compact interface design
  • Analog signal isolation
  • Current loop signal processing
  • Selected Ex-approved configurations
  • Flexible field instrument integration

Typical applications:

  • Industrial signal isolation
  • Process instrumentation
  • Analog measurement transmission
  • Control cabinet installations

9. Safety Barriers – Hazardous-Area Protection

TURCK safety barriers protect signal circuits and provide safe electrical interfaces between hazardous and non-hazardous areas.

Available functions include:

  • Intrinsic safety barriers
  • Analog input barriers
  • Analog output barriers
  • Digital input barriers
  • Digital output barriers
  • Switching amplifier functions
  • Isolated power supply interfaces

10. Control Cabinet Monitoring

TURCK control cabinet monitoring devices monitor operating conditions inside electrical control cabinets.

Depending on the device, monitoring functions include:

  • Internal cabinet temperature
  • Relative humidity
  • Operating condition monitoring
  • Alarm and status signaling
  • Remote cabinet condition monitoring

04. Available Models & Technical Specifications

TURCK offers a wide range of interface modules, signal isolators, and temperature measuring amplifiers.

The following are representative products listed in the official TURCK product catalog.

A. IM12 / IMX12 Signal Isolators

Model Product Type Channels Supply Voltage
IM12-AI01-1I-1IU-H0/24VDC/CC Isolating transducer 1 24 VDC
IM12-AO01-1I-1I-H0/24VDC/CC Analog signal isolator 1 24 VDC
IM12-AO01-2I-2I-H0/24VDC/CC Analog signal isolator 2 24 VDC
IMX12-AI01-1I-2IU-H0/24VDC/CC Isolating transducer 1 24 VDC
IMX12-AI01-1I-1IU1R-HPR/24VDC/CC Isolating transducer 1 24 VDC

B. IMXK12 Compact Interface Modules

Model Product Type Channels Supply Voltage
IMXK12-AI01-1I-1I-H0/24VDC Isolating transducer 1 24 VDC
IMXK12-AO01-1I-1I-H0/24VDC Analog signal isolator 1 24 VDC
IMXK12-DI01-1S-1T-0/24VDC Isolating switching amplifier 1 24 VDC
IMXK12-DI01-1S-1PP-0/24VDC Isolating switching amplifier 1 24 VDC

C. IM18 / IMX18 Switching Amplifiers

Model Product Type Channels Supply Voltage
IM18-DI03-4S-4T1R-S/24VDC Isolating switching amplifier 4 24 VDC
IM18-DI03-4S-5R-S/24VDC Isolating switching amplifier 4 24 VDC
IMX18-DI03-4S-5R-S/24VDC/CC Isolating switching amplifier 4 24 VDC
IMX18-DI03-4S-4T1R-S/24VDC/CC Isolating switching amplifier 4 24 VDC

D. IM33 / IM34 Measuring Amplifiers

Model Product Type Channels Application
IM33-11EX-HI/24VDC Isolating transducer 1 Analog input, HART transparent
IM33-12EX-HI/24VDC Isolating transducer 1 Analog input, HART transparent
IM34-11EX-I Temperature measuring amplifier 1 Temperature input
IM34-12EX-RI Temperature measuring amplifier 1 Temperature input

General Technical Specifications

Parameter Available Configurations
Product Types Signal isolators, safety barriers, switching amplifiers, measuring amplifiers
Signal Types Analog input/output, digital input, temperature input
Analog Signals Current and voltage, model-dependent
Temperature Inputs RTD and thermocouple configurations
Communication HART-transparent transmission on selected models
Channel Configurations Single-channel and multi-channel
Supply Voltage 24 VDC and wide-range variants
Installation DIN rail mounting
Hazardous-Area Protection Selected ATEX and IECEx configurations
Additional Approvals cULus, cFMus, INMETRO and other model-specific certifications
Output Types Analog, relay, transistor and model-specific outputs
Application Industrial instrumentation and process control

Important: Not every product supports all listed signals or approvals. Verify input/output configuration, isolation ratings, Ex certification, power supply, and wiring diagrams against the individual product datasheet.

05. Industrial & Mobile Applications

TURCK interface technology is widely used in industrial process instrumentation and control systems.

Oil & Gas

  • Hazardous-area signal isolation
  • Pressure and flow transmitter interfaces
  • Temperature measurement
  • Intrinsically safe field instrument connections
  • Process control system integration

Chemical & Petrochemical Industries

  • Ex-zone instrumentation
  • Analog process signal isolation
  • Temperature measurement amplification
  • Digital switching signal processing
  • Process safety interfaces

Pharmaceutical Manufacturing

  • Temperature sensor signal conditioning
  • Process instrumentation isolation
  • Industrial measurement interfaces
  • Control cabinet monitoring
  • Production process monitoring

Water & Wastewater Treatment

  • Level measurement signal isolation
  • Flow transmitter interfaces
  • Analog signal conversion
  • Pump and valve status monitoring
  • Process automation integration

Power Generation & Energy

  • Temperature measurement
  • Electrical signal isolation
  • Process instrument interfaces
  • Industrial control cabinet monitoring
  • Remote signal conditioning

Industrial Manufacturing

  • PLC analog signal isolation
  • Sensor signal conversion
  • Digital switching amplification
  • Control cabinet signal distribution
  • Machine monitoring systems

06. More Models & Technical Specifications

TURCK provides additional interface modules and signal conditioning configurations for different industrial requirements.

IM12 Series

  • Analog input isolators
  • Analog output isolators
  • HART-transparent isolating transducers
  • Temperature measuring amplifiers
  • Single-channel and dual-channel devices

IMX12 Series

  • Intrinsically safe analog input isolators
  • Analog output isolators
  • HART-transparent interfaces
  • Temperature measuring amplifiers
  • Ex-approved process signal interfaces

IMXK12 Series

  • Compact analog isolators
  • Compact switching amplifiers
  • Intrinsically safe input interfaces
  • Analog input and output configurations
  • HART-transparent variants

IM18 / IMX18 Series

  • Multi-channel switching amplifiers
  • Digital input isolators
  • Relay output interfaces
  • Transistor output interfaces
  • Intrinsically safe switching amplifiers

IM33 / IM34 Series

  • Analog isolating transducers
  • HART-transparent isolators
  • RTD measuring amplifiers
  • Thermocouple measuring amplifiers
  • Temperature signal conversion modules

IMC Series

  • Compact analog signal isolators
  • Current loop signal conditioners
  • Intrinsically safe interface variants
  • Industrial signal conversion modules

Additional Interface Technology

  • Intrinsic safety barriers
  • Analog signal conditioning devices
  • Digital signal isolation modules
  • Control cabinet temperature monitors
  • Humidity monitoring devices
  • Cabinet condition monitoring accessories

Key Selection Parameters

When selecting a TURCK interface module or signal conditioner, buyers should confirm:

  • Required signal type
  • Analog current or voltage input
  • Digital switching input requirements
  • RTD or thermocouple compatibility
  • Required input and output ranges
  • Number of channels
  • Galvanic isolation requirements
  • Intrinsic safety and hazardous-area classification
  • Required ATEX, IECEx, or other certifications
  • HART communication requirements
  • Relay or transistor output configuration
  • Supply voltage
  • DIN rail mounting requirements
  • Ambient operating temperature
  • Control cabinet space and installation requirements
  • Compatibility with PLC and process control systems

For additional TURCK signal isolators, safety barriers, temperature measuring amplifiers, technical datasheets, or industrial interface sourcing inquiries, please contact our online customer support team.